DC Generator & DC Motor question solutions for EEE job exams. 5 written questions and 23 math problems on DC Generator & DC Motor, the kind asked in Bangladesh EEE recruitment exams (BPDB, PGCB, DPDC, DESCO, NWPGCL, EGCB, BCS and others), each solved in exam style: the given data, what is required, the formula used at every step, the substitution and the final answer.
This post is part 9 of the EEE Job Preparation Question Bank series. It covers the DC generator and DC motor with 28 solved questions: 5 written (theory) questions and 15 math problems from recruitment exams (DESCO, PGCB, NWPGCL, RPGCL, BAPEX) and BUET M.Sc. admission tests, plus 8 practice problems on the same topics.
The answers are written for learning, not only for checking. A written answer explains what the thing is, why it is so, how it works and where it is used; where a question says "draw", the diagram is built up one step at a time. A math solution is laid out the way an examiner wants to see it: the given data with symbols and values, the quantity required, and then each step as formula → substitution → result, with the reason for that step written beside it. It also shows how to think about that type of problem, a diagram, and what to keep in mind.
How to use this post: every answer is hidden. Try the question on paper first, then click Show full answer or Show step-by-step solution. The grey tag beside a question shows the exam it came from.
- Formulas to memorize first
- Part A: Written questions (5)
- Part B: Solved problems (23)
Show the list
- Generated e.m.f. of a shunt generator
- E.m.f. of a shunt machine as generator and as motor
- Power developed by a shunt machine as generator and as motor
- Generated e.m.f. of a long-shunt compound generator
- Generated e.m.f. of a long-shunt compound generator with brush drop
- Generated e.m.f. of a short-shunt compound generator
- Generated e.m.f. of a compound generator with a diverter
- E.m.f. of a lap winding and the speed for a wave winding
- Generated e.m.f. and electrical efficiency of a shunt generator
- Terminal voltage and output of a long-shunt compound generator
- Load current of a generator at a lower speed
- Critical resistance and field resistance from an O.C.C.
- Efficiency of a DC shunt generator at 0 % and 25 % load
- Efficiency of a long-shunt compound generator
- Speed at which iron loss is halved
- Speed of a DC shunt machine as motor and as generator
- Speed of a shunt motor after field weakening
- Resistance added to halve a shunt motor's speed
- Speed of a shunt motor with resistance added in the armature
- Resistance to reduce a series motor's speed
- Shaft torque of a DC shunt motor
- Speed, armature torque and shaft torque of a 4-pole shunt motor
- Line current of a shunt motor when its speed falls on load
- Other parts of this series
Formulas to Memorize First
- E.m.f. equation: E = ΦZN/60 × (P/A). Lap winding A = P; wave winding A = 2.
- Generator: E = V + IaRa (+ brush drop), and Ia = IL + Ish. The armature feeds both the load and the field.
- Motor: Eb = V − IaRa, and Ia = IL − Ish. The line feeds both the armature and the field.
- Long shunt: the series field carries Ia, so add Rse to Ra.
- Speed: N ∝ Eb/Φ. With constant flux, N ∝ Eb.
- Torque: T ∝ ΦIa. Shunt motor: T ∝ Ia. Series motor (unsaturated): T ∝ Ia².
- Power and torque: developed power = EbIa; T = P/ω with ω = 2πN/60.
- Losses: copper (armature, series field, shunt field), iron (hysteresis ∝ N, eddy ∝ N²), mechanical (friction, windage).
- Efficiency: constant losses stay the same, armature copper loss goes as (load)². Maximum efficiency when the two are equal.
- Voltage build-up: a shunt generator builds up only if its field resistance is less than the critical resistance.
Part A: Written Questions on DC Machines
Q1. List the losses in a DC compound generator. BEPZA, MIST
Show full answer
Short answer (write this in the exam)
- Copper losses: armature copper loss Ia²Ra, series-field copper loss, shunt-field copper loss, and the brush-contact loss.
- Iron (core) losses: hysteresis loss and eddy-current loss in the armature core.
- Mechanical losses: bearing and brush friction, and windage (air friction).
What happens to the input power
The prime mover gives mechanical power to the shaft. First the mechanical and iron losses are taken out; these are together called the stray or rotational losses. What remains is converted to electrical power E × Ia in the armature. Then the copper losses are taken out, and the rest reaches the load.
Why each loss occurs
- Copper loss: every winding has resistance, so current through it produces heat I²R. A compound generator has three windings, so three copper losses.
- Hysteresis loss: each part of the rotating armature core passes under N and S poles in turn, so its magnetism reverses again and again. Wh ∝ B1.6 × f, and f is proportional to speed.
- Eddy-current loss: the rotating core cuts the field, so currents are induced in the iron itself. We ∝ B²f²t². It is reduced by laminating the core.
- Mechanical loss: friction in the bearings and at the brushes, and the air drag on the rotating armature.
How they are grouped for efficiency problems
Constant losses = iron + mechanical + shunt-field copper loss (they do not change with load at constant speed and voltage). Variable loss = armature and series-field copper loss, which changes as the square of the load current. Efficiency is maximum when variable loss = constant loss.
Keep in mind
Three families: copper, iron, mechanical. In a compound machine name all three copper losses (armature, series field, shunt field). Iron loss is in the armature core, because that is the part where the flux changes.
Q2. Draw typical open-circuit characteristic (OCC) curves of a DC shunt generator at two speeds n₁ and n₂ (n₁ > n₂). DESCO
Show full answer
What the OCC is
The open-circuit characteristic (also called the magnetisation curve or no-load saturation curve) is the graph of generated e.m.f. E against field current If, taken at constant speed with no load on the machine.
How to draw it (three steps)
Each picture adds one step to the one before it. Draw it on paper in the same order.
Drawing step 3 of 3. Add the field-resistance line, a straight line through the origin whose slope is Rf = V/If. Where it cuts each curve is the voltage to which the shunt generator builds up at that speed.Why the curve has this shape
- Residual part: the poles keep a little magnetism from earlier use, so a small e.m.f. (2 to 5 % of rated) appears at If = 0. Without it a shunt generator could not start to build up.
- Straight part: flux is proportional to field current while the iron is unsaturated, and E ∝ Φ.
- Bend (knee) and flat part: the iron saturates, so more field current gives little more flux.
What the two speeds tell you
From E = ΦZN/60 × (P/A), for the same If: E1/E2 = n1/n2. So a higher speed gives a higher build-up voltage, and also a higher critical field resistance (the slope of the straight part). For a given field resistance there is a critical speed below which the field line no longer cuts the curve and the generator fails to build up.
Keep in mind
Same shape, scaled by speed. The curve starts above zero (residual voltage). Operating point = intersection of the OCC and the field-resistance line.
Q3. Name the methods of speed control of a DC shunt motor. DESCO
Show full answer
Short answer (write this in the exam)
- Flux (field) control: a rheostat in series with the shunt field.
- Armature (rheostatic) control: a resistance in series with the armature.
- Armature-voltage control: a variable voltage applied to the armature (Ward-Leonard set, or a thyristor converter or chopper).
Where the three methods come from
The speed equation is N ∝ Eb/Φ = (V − IaRa)/Φ. Only three things can be changed: the flux Φ, the drop in the armature circuit, or the applied voltage V. That gives exactly three methods.
How each method works, and its limits
| Method | How | Speed range | Remarks |
|---|---|---|---|
| Flux control | Increase the field rheostat → If and Φ fall → N rises | Above base speed | Cheap and efficient (the field current is small). Limited by weak-field commutation problems; constant-power drive. |
| Armature resistance | Extra R drops voltage → Eb falls → N falls | Below base speed | Wasteful: large Ia²R loss, and the speed changes a lot with load. |
| Armature voltage | Reduce V at constant flux → N falls in proportion | Below base speed, smoothly down to zero | Efficient and smooth, constant-torque drive, but needs a variable DC source. |
Where they are used
Flux control: lathes and machine tools needing speeds above normal. Armature resistance: small motors and short-time speed reduction. Armature voltage: rolling mills, lifts, paper mills and modern electronic DC drives. Combining armature-voltage control (below base speed) with field weakening (above base speed) gives a very wide range.
Keep in mind
Weakening the field raises the speed; adding armature resistance or lowering the voltage lowers it. Never open the field circuit of a running shunt motor: Φ falls to the residual value and the motor races dangerously.
Q4. Why can the speed of a d.c. motor not be increased above the rated speed using the armature voltage control method? NWPGCL
Show full answer
Short answer (write this in the exam)
With armature-voltage control at constant flux, N ∝ V − IaRa, so the speed is proportional to the armature voltage. The highest voltage that may be applied is the rated voltage, and that gives the rated (base) speed. Going faster would need more than rated voltage, which the insulation and the commutator cannot withstand. So this method works only below rated speed.
Why the voltage cannot be raised further
- The winding insulation is designed for rated voltage.
- The voltage between adjacent commutator segments would become too high, causing sparking and flash-over at the brushes.
- The core is already working at its designed flux, so there is no margin there either.
How speeds above rated are obtained
Above base speed the flux is reduced (field weakening): since N ∝ Eb/Φ, a smaller Φ gives a higher speed with the same voltage. The armature current is still limited to its rated value, so the power V × Ia stays constant while the torque (∝ ΦIa) falls.
Keep in mind
Below base speed: vary V, full flux, constant torque. Above base speed: rated V, weaker flux, constant power. Base speed is the speed at rated voltage and full field.
Q5. Draw the diagram of a starter for a d.c. motor. PGCB
Show full answer
Why a starter is needed
At the instant of starting the armature is at rest, so the back e.m.f. Eb = 0. The armature current would be Ia = V/Ra, and Ra is very small. For example, a 220 V motor with Ra = 0.5 Ω would draw 440 A, many times its full-load current. That would burn the commutator and winding, give a violent torque jerk, and dip the supply voltage. A starter puts a resistance in series with the armature at the start and removes it step by step as the motor speeds up and Eb builds.
How to draw the three-point starter (three steps)
Each picture adds one step to the one before it. Draw it on paper in the same order.
How it works
- Move the handle to the first stud: the field is fully excited and the armature is connected through the whole resistance, so the starting current is limited (to about 1.5 times full load).
- As the motor accelerates, Eb rises and the current falls. Move the handle slowly across the studs, cutting out resistance.
- At ON the resistance is all out. The soft-iron piece on the handle is held by the no-volt coil.
- If the supply fails (or the field opens), the no-volt coil loses its magnetism and the spring returns the handle to OFF, so the motor cannot restart directly across the line.
- If the motor is overloaded, the overload release pulls up an arm that short-circuits the no-volt coil, and the handle is released.
Where the name comes from
It has three terminals: L (line), A (armature) and F (field). A four-point starter has a separate circuit for the no-volt coil so that weakening the field for speed control does not release the handle.
Keep in mind
Starting current = V/Ra because Eb = 0. Starter = series resistance + no-volt release + overload release. Terminals L, A, F.
Part B: Solved Problems on DC Machines
Problem 1. Generated e.m.f. of a shunt generator RPGCL
A shunt generator delivers 450 A at 230 V. The shunt field resistance is 50 Ω and the armature resistance is 0.03 Ω. Find the generated e.m.f.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| IL | 450 A | load current |
| V | 230 V | terminal voltage |
| Rsh | 50 Ω | shunt field |
| Ra | 0.03 Ω | armature |
- E
- Generator: Ia = IL + Ish and E = V + IaRa.
Problem 2. E.m.f. of a shunt machine as generator and as motor EGCB
A 220 V shunt d.c. machine has Ra = 0.5 Ω and Rsh = 110 Ω. The full-load line current is 20 A. Find the induced e.m.f. when it works as a generator and as a motor.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| V | 220 V | supply |
| Ra | 0.5 Ω | armature |
| Rsh | 110 Ω | shunt field |
| IL | 20 A | line current |
- Eg (generator)
- Eb (motor)
The same machine in the two modes. Only the current directions differ.- Generator: Ia = IL + Ish, E = V + IaRa. Motor: Ia = IL − Ish, Eb = V − IaRa.
- A quick check: generator e.m.f. is always above V, motor back e.m.f. always below V.
Problem 3. Power developed by a shunt machine as generator and as motor Practice problem
A 25 kW, 250 V d.c. shunt machine has an armature resistance of 0.06 Ω and a shunt field resistance of 100 Ω. Find the power developed in the armature when it runs (i) as a generator delivering 25 kW output, (ii) as a motor taking 25 kW input.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 25 kW | output (gen) or input (motor) |
| V | 250 V | terminal |
| Ra | 0.06 Ω | armature |
| Rsh | 100 Ω | shunt field |
- Pdev (generator and motor)
- Generator: Ia = IL + Ish, E = V + IaRa.
- Motor: Ia = IL − Ish, Eb = V − IaRa.
- Power developed = E Ia (conversion power).
Problem 4. Generated e.m.f. of a long-shunt compound generator DNCC
A 4-pole, long-shunt, lap-wound generator supplies 25 kW at 500 V. Ra = 0.03 Ω, series field 0.04 Ω, shunt field 200 Ω and brush drop 1.0 V. Find the generated e.m.f., and the number of conductors if the speed is 1200 rpm and the flux per pole is 0.02 Wb.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 25 kW | output |
| V | 500 V | terminal |
| Ra | 0.03 Ω | |
| Rse | 0.04 Ω | |
| Rsh | 200 Ω | |
| Vb | 1.0 V | brush drop |
| N | 1200 rpm | |
| Φ | 0.02 Wb | |
| P | 4 | lap |
- E
- Z
- Long shunt: E = V + Ia(Ra + Rse) + brush drop.
- Lap: A = P. Wave: A = 2.
- Z comes out as a whole number of conductors; round sensibly.
Problem 5. Generated e.m.f. of a long-shunt compound generator with brush drop Practice problem
A long-shunt compound generator supplies a load current of 50 A at 500 V. The armature resistance is 0.05 Ω, the series field resistance is 0.03 Ω and the shunt field resistance is 250 Ω. Allow a contact drop of 1 V at each brush. Find the generated e.m.f.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| IL | 50 A | load current |
| V | 500 V | terminal |
| Ra | 0.05 Ω | |
| Rse | 0.03 Ω | |
| Rsh | 250 Ω | |
| Vb | 1 V per brush |
- Eg
- Long shunt: Ia = IL + Ish and E = V + Ia(Ra + Rse) + brush drop.
- "1 V per brush" means 2 V in total for the usual two-brush path.
Problem 6. Generated e.m.f. of a short-shunt compound generator Practice problem
A short-shunt compound generator delivers 30 A to a load at 220 V. Its armature, series field and shunt field resistances are 0.05 Ω, 0.30 Ω and 200 Ω. Allow a contact drop of 1 V per brush. Find the induced e.m.f. and the armature current.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| IL | 30 A | load current |
| V | 220 V | terminal |
| Ra | 0.05 Ω | |
| Rse | 0.30 Ω | |
| Rsh | 200 Ω | |
| Vb | 1 V per brush |
- Ia
- Eg
- Short shunt: Vsh = V + IL Rse, Ia = IL + Ish, E = V + IL Rse + Ia Ra + brush drop.
- Long shunt: Vsh = V, and the series field carries Ia.
Problem 7. Generated e.m.f. of a compound generator with a diverter Practice problem
A 300 kW, 600 V long-shunt compound generator has these resistances: shunt field 75 Ω, armature (including brushes) 0.03 Ω, commutating (interpole) field 0.011 Ω, series field 0.012 Ω. A diverter of 0.036 Ω is connected in parallel with the series field. At full load, find the generated e.m.f. and the power developed in the armature.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 300 kW | output |
| V | 600 V | terminal |
| Rsh | 75 Ω | |
| Ra | 0.03 Ω | with brushes |
| Ri | 0.011 Ω | interpole |
| Rse | 0.012 Ω | |
| Rd | 0.036 Ω | diverter |
- Eg
- Pdev
The diverter sits in parallel with the series field. Together they act as 0.009 Ω in the armature branch.- Diverter: Reff = Rse Rd/(Rse + Rd), always less than Rse.
- Interpole and compensating windings always carry the armature current.
- Power developed = E Ia = output + all copper losses (and brush loss).
Problem 8. E.m.f. of a lap winding and the speed for a wave winding Practice problem
An 8-pole d.c. generator has 500 armature conductors and a useful flux of 0.05 Wb per pole. What e.m.f. is generated when it is lap-wound and runs at 1200 r.p.m.? At what speed must it run to give the same e.m.f. if the armature is wave-wound?
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 8 | poles |
| Z | 500 | conductors |
| Φ | 0.05 Wb | flux per pole |
| N | 1200 rpm | lap speed |
- E (lap)
- N (wave, same E)
- E = ΦZNP/(60A).
- Lap: A = P (high current, low voltage). Wave: A = 2 (high voltage, low current).
- For the same E, N is proportional to A/P.
Problem 9. Generated e.m.f. and electrical efficiency of a shunt generator Practice problem
A shunt generator delivers 20 A to a 10 Ω load. The armature resistance is 0.5 Ω and the shunt field resistance is 50 Ω. Allow 1 V per brush. Find the e.m.f. generated and the electrical efficiency.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| IL | 20 A | load current |
| RL | 10 Ω | load |
| Ra | 0.5 Ω | |
| Rsh | 50 Ω | |
| Vb | 1 V per brush |
- Eg
- ηe
- ηe = VIL/(EIa).
- Overall efficiency = mechanical × electrical.
- A low-resistance shunt field (50 Ω here) wastes a lot: 4 A × 200 V = 800 W.
Problem 10. Terminal voltage and output of a long-shunt compound generator PGCL
A 4-pole, lap-wound, long-shunt d.c. compound generator has a useful flux per pole of 0.07 Wb. The armature winding consists of 220 turns and the resistance per turn is 0.004 Ω. Calculate the terminal voltage if the resistances of the shunt and series fields are 100 Ω and 0.02 Ω respectively, when the generator is running at 900 rpm with an armature current of 50 A. Also calculate the power output in kW.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 4 | lap |
| Φ | 0.07 Wb | flux per pole |
| turns | 220 | armature |
| r | 0.004 Ω/turn | |
| Rsh | 100 Ω | |
| Rse | 0.02 Ω | |
| N | 900 rpm | |
| Ia | 50 A |
- V
- Pout
- Ra = (resistance of all turns in series) ÷ A².
- Output power uses the load current, not the armature current.
Problem 11. Load current of a generator at a lower speed BAPEX
A separately excited generator running at 1000 rpm supplies 200 A at 125 V. What is the load current when the speed drops to 800 rpm with the field current unchanged? Ra = 0.04 Ω and the total brush drop is 2 V (the load resistance is unchanged).
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| N₁ | 1000 rpm | |
| I₁ | 200 A | load current |
| V₁ | 125 V | terminal |
| Ra | 0.04 Ω | |
| Vb | 2 V | brush drop |
| N₂ | 800 rpm |
- I₂
- Constant field: E1/E2 = N1/N2.
- Brush drop is a fixed voltage, not a resistance.
Problem 12. Critical resistance and field resistance from an O.C.C. DWASA
From the O.C.C. curve calculate the critical resistance Rc and the field resistance Rsh. The critical-resistance line T passes through the point C (field current 0.5 A, 100 V); the field-resistance line meets the O.C.C. at B (3.75 A, 165 V).
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| C | 0.5 A, 100 V | point on the critical line |
| B | 3.75 A, 165 V | operating point |
- Rc
- Rsh
- Resistance = slope = V/If of a point on the line.
- Conditions for build-up: residual magnetism, correct field polarity, Rf below critical, speed above critical.
Problem 13. Efficiency of a DC shunt generator at 0 % and 25 % load
A 10 kW DC shunt generator has mechanical 290 W, iron 420 W, shunt Cu 120 W, armature Cu 595 W at full load. Find η at no load and at 25 % load.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 10 kW | rating |
| Pm | 290 W | mechanical |
| Pi | 420 W | iron |
| Psh | 120 W | shunt copper |
| Pa | 595 W | full-load armature copper |
- η (at no load and 25 % load)
- Constant loss stays; armature copper loss × (load fraction)².
- At light load the constant loss dominates, so efficiency is poor.
Problem 14. Efficiency of a long-shunt compound generator APSCL
A long-shunt compound generator gives 240 V at a full-load output of 100 A. The armature (with brushes) is 0.1 Ω, series field 0.02 Ω, interpole field 0.025 Ω and shunt field (with regulator) 100 Ω. The iron loss at full load is 1000 W and windage and friction losses are 500 W. Calculate the full-load efficiency.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| V | 240 V | terminal |
| IL | 100 A | load |
| Ra | 0.1 Ω | |
| Rse | 0.02 Ω | |
| Ri | 0.025 Ω | |
| Rsh | 100 Ω | |
| Pi | 1000 W | iron |
| Pfw | 500 W | friction, windage |
- η
- Efficiency of a generator = output/(output + losses).
- Include interpole (commutating) windings with the armature circuit.
Problem 15. Speed at which iron loss is halved BUET M.Sc.
A DC machine at 1000 rpm has hysteresis loss 250 W and eddy-current loss 100 W. At what speed is the total iron loss halved (flux constant)?
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| Ph | 250 W | hysteresis at 1000 rpm |
| Pe | 100 W | eddy at 1000 rpm |
- N (for half the iron loss)
- Wh ∝ N and We ∝ N² at constant flux.
- Halving the loss does not mean halving the speed.
Problem 16. Speed of a DC shunt machine as motor and as generator BUET M.Sc.
A 200 V DC shunt machine has Ra = 0.5 Ω and Rf = 200 Ω. As a motor it runs at 1000 rpm drawing 31 A. At what speed must it be driven as a generator to deliver the same 31 A at 200 V?
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| V | 200 V | supply |
| Ra | 0.5 Ω | |
| Rf | 200 Ω | |
| Nm | 1000 rpm | motor speed |
| IL | 31 A | line current |
- Ng (generator speed)
Same flux in both, so speed is in the ratio of the e.m.f.s: 216/185.- N2/N1 = E2/E1 when Φ is constant.
- The same machine needs a higher speed as a generator than as a motor at the same voltage.
Problem 17. Speed of a shunt motor after field weakening ERL
A 500 V shunt motor runs at 250 rpm with an armature current of 200 A and Ra = 0.12 Ω. Find its speed when the shunt field is reduced to 80 % of normal and the armature current is 100 A.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| V | 500 V | supply |
| N₁ | 250 rpm | |
| Ia1 | 200 A | |
| Ra | 0.12 Ω | |
| Φ₂ | 0.8Φ₁ | field weakened |
| Ia2 | 100 A |
- N₂
- N2/N1 = (Eb2/Eb1)(Φ1/Φ2).
- Field weakening increases speed.
Problem 18. Resistance added to halve a shunt motor's speed DNCC
A 250 V shunt motor has an armature current of 20 A at 1000 rpm against full-load torque, with Ra = 0.5 Ω. What resistance must be inserted in series with the armature to reduce the speed to 500 rpm at the same torque, and what will the speed be if the load torque is halved with this resistance in circuit? (Flux constant.)
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| V | 250 V | supply |
| Ia | 20 A | full-load torque |
| N₁ | 1000 rpm | |
| Ra | 0.5 Ω | |
| N₂ | 500 rpm | target |
- R (added resistance)
- N (at half torque)
- Constant flux: T ∝ Ia and N ∝ Eb.
- With a series resistance the speed changes strongly with load: 500 rpm at full torque, 771 rpm at half torque.
Problem 19. Speed of a shunt motor with resistance added in the armature BAPEX
A 250 V shunt motor with armature resistance 0.5 Ω runs at 600 rpm on full load and takes an armature current of 20 A. If a resistance of 1 Ω is placed in the armature circuit, find the speed at full-load torque.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| V | 250 V | supply |
| Ra | 0.5 Ω | |
| N₁ | 600 rpm | |
| Ia | 20 A | full load |
| Rx | 1 Ω | added |
- N₂
- Adding armature resistance lowers Eb and so lowers the speed, at the cost of I²R loss.
Problem 20. Resistance to reduce a series motor's speed BWDB
A 240 V d.c. series motor takes 40 A at 3000 rpm giving its rated output. Its resistance is 0.6 Ω. What resistance must be added to obtain the same torque at 2000 rpm?
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| V | 240 V | supply |
| I | 40 A | current |
| N₁ | 3000 rpm | |
| Rm | 0.6 Ω | motor resistance |
| N₂ | 2000 rpm | target |
- Rx
- Series motor: same torque → same current → same flux.
- Never run a series motor without load: the flux becomes very small and the speed dangerously high.
Problem 21. Shaft torque of a DC shunt motor BUET M.Sc.
A d.c. shunt motor is connected to a 240 V supply and runs at 1500 rpm with Ra = 0.68 Ω and an armature current of 40 A. Friction and windage loss is 600 W. Find the shaft torque.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| V | 240 V | supply |
| N | 1500 rpm | |
| Ra | 0.68 Ω | |
| Ia | 40 A | |
| Pfw | 600 W | friction, windage |
- Tsh
- Armature torque = EbIa/ω; shaft torque = output/ω.
- ω = 2πN/60.
Problem 22. Speed, armature torque and shaft torque of a 4-pole shunt motor Practice problem
A 4-pole, 220 V shunt motor has 540 lap-wound conductors. It takes 32 A from the supply and delivers 5.595 kW of output. The field current is 1 A, the armature resistance is 0.09 Ω and the flux per pole is 30 mWb. Find (i) the speed and (ii) the torque developed by the armature and the useful (shaft) torque.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 4 | lap |
| V | 220 V | supply |
| Z | 540 | conductors |
| IL | 32 A | line current |
| Pout | 5.595 kW | |
| If | 1 A | |
| Ra | 0.09 Ω | |
| Φ | 30 mWb |
- N
- Ta
- Tsh
- Ta = 0.159ΦZIa(P/A) = EbIa/ω.
- Tsh = Pout/ω; Ta − Tsh = torque lost to iron and friction losses.
- N = 60AEb/(ΦZP).
Problem 23. Line current of a shunt motor when its speed falls on load Practice problem
A 230 V d.c. shunt motor has an armature resistance of 0.5 Ω and a field resistance of 115 Ω. At no load it runs at 1200 r.p.m. with an armature current of 2.5 A. When rated load is applied the speed falls to 1120 r.p.m. Find the line current and the power input at rated load.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| V | 230 V | supply |
| Ra | 0.5 Ω | |
| Rsh | 115 Ω | |
| N₀ | 1200 rpm | no load |
| Ia0 | 2.5 A | no load |
| N₁ | 1120 rpm | rated load |
- IL
- Pin
- Shunt motor: Eb ∝ N because Φ is constant.
- Speed falls only a little (about 7 %) while the armature current rises many times: a shunt motor is nearly a constant-speed motor.
- Line current = Ia + Ish.
- DC Circuit Analysis
- Network Theorems
- RL, RC & RLC Transients
- Single-Phase AC Circuits
- Series & Parallel Resonance
- Power Factor Correction
- Three-Phase Circuits
- Transformer
- DC Generator & DC Motor (this post)
- Three-Phase Induction Motor
- Synchronous Machines
- Diode Circuits
- BJT Biasing & Amplifiers
- MOSFET & Power Electronics
- Op-Amp Circuits
- AM, FM & Analog Modulation
- Signals and Sampling
- PCM, Delta Modulation & TDM
- Digital Communication & Telecom
- Load Curves & Power Generation
- Per-Unit & Transmission Lines
- Faults & Symmetrical Components
- Protection & Switchgear
- Control Systems
- Digital Logic & Microprocessors
- Measurement, Mechanics & Aptitude
Topics shown in grey are coming soon. See every post in this series.
Found a mistake or have a better method? Leave a comment below. More topics from the question bank are in the other posts of this series.
Thank you for visiting my blog.