Load Curves & Power Generation question solutions for EEE job exams. 6 written questions and 46 math problems on Load Curves & Power Generation, the kind asked in Bangladesh EEE recruitment exams (BPDB, PGCB, DPDC, DESCO, NWPGCL, EGCB, BCS and others), each solved in exam style: the given data, what is required, the formula used at every step, the substitution and the final answer.
This post is part 20 of the EEE Job Preparation Question Bank series. It covers load curves and power generation with 52 solved questions: 6 written (theory) questions on steam, coal and nuclear power plants, plant efficiencies and the Bangladesh power sector and 23 math problems on load factor, demand factor, diversity factor, capacity and utilisation factors, reserve capacity, load-duration curves, tariffs, fuel cost and outage probability from recruitment exams (BPDB, PGCB, NWPGCL, EGCB, APSCL, BIFPCL, DPDC, DWASA) and BUET M.Sc. admission tests, plus 23 practice problems on the same topics.
The answers are written for learning, not only for checking. A written answer explains what the thing is, why it is so, how it works and where it is used; where a question says "draw", the diagram is built up one step at a time. A math solution is laid out the way an examiner wants to see it: the given data with symbols and values, the quantity required, and then each step as formula → substitution → result, with the reason for that step written beside it. It also shows how to think about that type of problem, a diagram, and what to keep in mind.
How to use this post: every answer is hidden. Try the question on paper first, then click Show full answer or Show step-by-step solution. The grey tag beside a question shows the exam it came from.
- Formulas to memorize first
- Part A: Written questions (6)
Show the list
- What is the difference between feed water and cooling water of a steam…
- What are the main components of coal? Name some types of coal. How can…
- Define mechanical efficiency, heat (thermal) efficiency and plant…
- What is pulverisation? Why is demineralised water essential for the…
- Draw the block diagram of a nuclear power plant and list the…
- Give the main Bangladesh power-sector facts.
- Part B: Solved problems (46)
Show the list
- Load factor, capacity factor and reserve
- Demand factor and load factor of a station
- Annual energy from maximum demand and load factor
- Load, capacity and utilisation factors
- Plant capacity factor and utilisation factor
- Capacity factor and utilisation factor
- Load factor, plant capacity and reserve from the capacity and…
- Load, demand and diversity factors from a daily load pattern
- Diversity factor and load factor of a diesel station
- Load factor with a short evening peak
- Annual load factor of a station that is shut down part of the time
- Annual load factor from the daily load factor and the peak ratios
- Maximum demand, daily energy, average load and load factor from a load…
- Daily energy and average power of a household from its load curve
- Diversity factor and load factor from group loads
- Load factors of three consumers and of the station
- Load factor from the area of a load curve (planimeter)
- Load factor, capacity factor and utilisation factor from a…
- Annual energy and load factor from a linear load-duration curve
- Plant capacity factor and load factor with a linear load curve
- Load curve and load-duration curve of the same daily cycle
- Maximum demand and annual energy from diversity factor
- Maximum demand, annual energy and unit sizes for a new station
- Feeder maximum demand from group demand and diversity factors
- Maximum demand of a residential area
- Group maximum demand of a commercial group
- Increase in system peak from a residential-cum-shopping complex
- Maximum demand and connected loads from demand and diversity factors
- Minimum capacity of a diesel station for a suburban area
- Maximum demand from reserve capacity and factors
- Station capacity from annual energy and factors
- Capacity and reserve of a peak-load hydro plant
- Load factors and capacity factors of a base-load and a standby station
- Reserve capacity and energy from the plant factors
- Daily energy and reserve capacity of a power station
- Daily load factor, plant capacity factor and fuel per day
- Average cost per kWh from a two-part tariff
- Monthly bill with a demand charge and a two-block energy charge
- Domestic bill with a fixed charge and three energy blocks
- Thermal efficiency and coal cost of a station
- Calorific value of coal from overall efficiency and coal burnt per kWh
- Average load of a steam station from its annual coal bill
- Monthly fuel oil and overall efficiency of a diesel plant
- Probable forced outage of a generating system
- Energy intensity of a country
- Energy used by a set of bulbs
- Other parts of this series
Formulas to Memorize First
- Load factor = average load/maximum demand (over the stated period). Average load = energy/hours.
- Demand factor = maximum demand/connected load (≤ 1).
- Diversity factor = sum of individual maximum demands/maximum demand of the whole group (≥ 1).
- Plant capacity factor = average load/installed capacity = actual energy/(capacity × hours).
- Utilisation factor = maximum demand/installed capacity. Link: capacity factor = load factor × utilisation factor.
- Plant use factor = actual energy/(capacity × hours actually run).
- Reserve capacity = installed capacity − maximum demand.
- Hours: 24 h per day, 8760 h per year.
- Linear load-duration curve: average = (maximum + minimum)/2; energy = area under the curve.
- Chain for groups: connected load × demand factor ÷ group diversity ÷ peak diversity = demand at the system peak.
- Two-part tariff: annual cost = A × (kW of maximum demand) + B × (kWh); cost per kWh = total/kWh.
- Overall plant efficiency = product of boiler, turbine (thermal and mechanical) and generator efficiencies.
Part A: Written Questions on Load Curves, Plant Factors & Generation Economics
Q1. What is the difference between feed water and cooling water of a steam turbine plant? BIFPCL
Show full answer
Short answer
Feed water is the pure water that is pumped into the boiler and turned into steam; it circulates in a closed loop through the turbine and condenser. Cooling water is a large flow of ordinary water that passes through the condenser tubes to condense the exhaust steam; it never mixes with the steam.
Where each flows
Each picture adds one step to the one before it. Draw it on paper in the same order.
Comparison
| Point | Feed water | Cooling (circulating) water |
|---|---|---|
| Purpose | Becomes the steam that drives the turbine | Removes heat in the condenser |
| Circuit | Closed loop (condensate + small make-up) | Open or semi-closed (river, sea, cooling tower) |
| Quality | Very pure, demineralised, de-aerated, chemically treated | Ordinary water, filtered and treated only against fouling |
| Quantity | Equal to the steam flow | About 50–60 times the steam flow |
| Temperature | Pre-heated to 150–250 °C before the boiler | Near ambient; warms by about 8–10 °C |
Keep in mind
Feed water → boiler (pure, closed loop). Cooling water → condenser (large flow, never touches the steam).
Q2. What are the main components of coal? Name some types of coal. How can fuel quality be recognised? BIFPCL
Show full answer
Main components of coal
- Proximate analysis (what is usually reported): moisture, volatile matter, fixed carbon and ash.
- Ultimate analysis (elements): carbon, hydrogen, oxygen, nitrogen and sulphur.
Types of coal
- Peat: youngest, very wet, lowest heating value.
- Lignite (brown coal): high moisture, about 15 MJ/kg.
- Sub-bituminous.
- Bituminous: most common power-station coal (Barapukuria coal is bituminous), about 25–30 MJ/kg.
- Anthracite: hardest, highest carbon, burns with little smoke.
How fuel quality is recognised
- Calorific (heating) value, kJ/kg: the higher, the better.
- Moisture: low is better (moisture wastes heat).
- Ash: low is better (ash handling, erosion, lower heat value).
- Fixed carbon: high is better.
- Volatile matter: enough for easy ignition, not so much that it smokes.
- Sulphur: low (corrosion, SO₂ emission).
- Ash fusion temperature (slagging) and grindability (for pulverising mills).
Keep in mind
Proximate: moisture, volatile matter, fixed carbon, ash. Types: peat → lignite → sub-bituminous → bituminous → anthracite. Quality: high calorific value, low moisture/ash/sulphur.
Q3. Define mechanical efficiency, heat (thermal) efficiency and plant (overall) efficiency. BIFPCL
Show full answer
The energy flow
Definitions
- Mechanical efficiency = brake (shaft) power/indicated (internal) power. It accounts for friction and other mechanical losses in the prime mover.
- Heat (thermal) efficiency = heat equivalent of the useful work output/heat supplied by the fuel. For a fuel: ηth = work output/(fuel mass × calorific value).
- Plant (overall) efficiency = electrical energy sent out/heat energy of the fuel burnt. It equals ηboiler × ηthermal × ηmechanical × ηgenerator.
Typical values
| Plant | Overall efficiency |
|---|---|
| Steam (coal) plant | 30–40 % |
| Open-cycle gas turbine | 25–35 % |
| Combined-cycle gas plant | 50–60 % |
| Diesel plant | 35–40 % |
| Hydro plant | 85–90 % |
Keep in mind
ηmech = brake/indicated power; ηth = useful work/heat supplied; ηoverall = electrical output/fuel heat = product of all stage efficiencies.
Q4. What is pulverisation? Why is demineralised water essential for the boiler of a steam turbine power plant? BPDB
Show full answer
What pulverisation is
Pulverisation is grinding coal into a fine powder (about 70–75 % passing a 200-mesh sieve, i.e. finer than about 75 µm) in mills. The powder is carried by hot primary air into the burners and burns in suspension like a gas.
The pulverised-coal system
Each picture adds one step to the one before it. Draw it on paper in the same order.
Why pulverise
- Huge surface area → fast, complete combustion with little excess air → higher boiler efficiency.
- Quick response to load changes (like oil or gas firing).
- Low-grade coals can be burnt.
- No clinker problems on grates; large boilers become possible.
Why demineralised (DM) water is essential
- Scale: dissolved salts (calcium, magnesium, silica) deposit on the tube walls as the water boils. Scale is a poor heat conductor, so the tube metal overheats and can burst.
- Corrosion of tubes and drums by dissolved salts and gases.
- Carry-over: at high pressure, silica and salts are carried with the steam and deposit on the turbine blades, reducing efficiency and causing imbalance.
- Blow-down losses rise if impure water is used.
DM water has almost no ions, so it keeps the high-pressure boiler and the turbine clean.
Keep in mind
Pulverised coal: ~75 µm powder, burnt in suspension; better efficiency and control. DM water prevents scale, corrosion and carry-over to the turbine.
Q5. Draw the block diagram of a nuclear power plant and list the site-selection factors. NPCBL
Show full answer
Block diagram
Main parts
- Reactor core: fuel (enriched uranium), moderator, control rods; produces heat by fission.
- Primary loop and pressuriser: high-pressure water carries heat from the core to the steam generator.
- Steam generator: heat exchanger producing steam in the secondary loop.
- Turbine, generator, condenser and feed pumps: as in a steam plant.
- Containment: thick steel and concrete shell around the reactor.
Site-selection factors
- Cooling water: large, reliable supply (river or sea).
- Distance from population centres (exclusion zone) and impact on livelihoods.
- Seismic and geological safety, flood level.
- Land area and foundation strength.
- Transport access for heavy equipment and fuel.
- Waste disposal and emergency planning.
- Nearness to the load centre and the grid.
Bangladesh's Rooppur plant (Pabna, on the Padma) uses Russian VVER-1200 pressurised-water reactors, 2 × 1200 MW.
Keep in mind
Reactor → steam generator → turbine → generator; condenser + cooling water. Site: water, safety distance, seismic stability, land, transport, waste.
Q6. Give the main Bangladesh power-sector facts.
Show full answer
Organisations (founding dates)
| Organisation | Founded |
|---|---|
| BPDB (Bangladesh Power Development Board) | 1 May 1972 |
| REB (Rural Electrification Board) | October 1977 |
| DESCO | 1994 |
| PGCB (Power Grid Company of Bangladesh) | 21 November 1996 |
| DPDC | 25 October 2005 |
| CPGCBL (Matarbari 2 × 600 MW coal plant) | 5 September 2011 |
System voltages and frequency
Generation facts
- Kaptai (Karnaphuli) hydro: 230 MW, the only hydro plant.
- Rooppur nuclear plant: 2 × 1200 MW (VVER-1200).
- Installed grid capacity is about 28 900 MW (January 2026); the record generation is about 17 200 MW (29 April 2024). In August 2018 it was 18 753 MW with a peak of 11 387 MW.
- Planning targets: 40 000 MW by 2030 and 60 000 MW by 2041.
Capacity and peak figures change every year, so check the latest numbers on the BPDB website before an exam.
Keep in mind
230/400 V, 50 Hz; 11 and 33 kV distribution; 132, 230 and 400 kV transmission. BPDB 1972, REB 1977, PGCB 1996, DPDC 2005.
Part B: Solved Problems on Load Curves, Plant Factors & Generation Economics
Problem 1. Load factor, capacity factor and reserve
A power station has a maximum demand of 15 000 kW, an annual load factor of 50 % and a plant capacity factor of 40 %. Find the reserve capacity.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| MD | 15 000 kW | maximum demand |
| LF | 50 % | load factor |
| CF | 40 % | capacity factor |
- reserve capacity
- Average = LF × maximum demand.
- Capacity = average/CF.
- Reserve = capacity − maximum demand.
Problem 2. Demand factor and load factor of a station BOF, DPI
A station feeds a 43 MW connected load with maximum demand 20 MW and annual output 61.5 × 10⁶ kWh. Find demand factor and load factor. Also the energy in a year for 100 MW maximum demand at 40 % load factor.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| Pconn | 43 MW | connected load |
| MD | 20 MW | |
| E | 61.5 × 10⁶ kWh | annual output |
| (b) | 100 MW at 40 % LF |
- demand factor
- LF
- energy (b)
- DF = MD/connected load.
- LF = energy/(MD × 8760).
- Energy = MD × LF × 8760.
Problem 3. Annual energy from maximum demand and load factor Practice problem
The maximum demand on a power station is 100 MW and its annual load factor is 40 %. Find the energy generated in a year.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| MD | 100 MW | |
| LF | 40 % |
- annual energy
- E = MD × LF × 8760.
Problem 4. Load, capacity and utilisation factors ERL, APSCL, BCIC
Calculate the load factor, capacity factor and utilisation factor of a 100 MW power plant supplying a maximum load of 95 MW and an average load of 90 MW.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| C | 100 MW | capacity |
| MD | 95 MW | maximum load |
| Pavg | 90 MW | average load |
- LF
- CF
- UF
- LF = avg/max; CF = avg/capacity; UF = max/capacity.
- CF = LF × UF (0.947 × 0.95 = 0.90).
- All three are ≤ 1.
Problem 5. Plant capacity factor and utilisation factor NWPGCL
A plant has a rated capacity of 100 MW, an average load of 90 MW and a maximum load of 98 MW. Find the plant capacity factor and the utilisation (plant use) factor.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| C | 100 MW | rated |
| Pavg | 90 MW | |
| MD | 98 MW |
- CF
- UF
- CF = avg/capacity.
- UF = max/capacity.
- LF = avg/max = 0.918 here.
Problem 6. Capacity factor and utilisation factor BUET Admission
If the average load is 90 MW, the maximum load is 100 MW and the installed capacity is 110 MW in a power plant, what are its capacity factor and utilisation factor?
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| Pavg | 90 MW | |
| MD | 100 MW | |
| C | 110 MW | installed |
- CF
- UF
- CF = LF × UF: 0.9 × 0.909 = 0.818.
- Reserve = 10 MW.
- UF shows how much of the plant is used at peak.
Problem 7. Load factor, plant capacity and reserve from the capacity and utilisation factors Practice problem
The maximum demand of a power plant is 40 MW. Its plant capacity factor is 0.5 and its utilisation factor is 0.8. Find (a) the load factor, (b) the plant capacity, (c) the reserve capacity and (d) the annual energy production.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| MD | 40 MW | |
| CF | 0.5 | capacity factor |
| UF | 0.8 | utilisation factor |
- LF
- C
- reserve
- E
- CF = LF × UF.
- Plant capacity = MD/UF; reserve = capacity − MD.
- Energy = LF × MD × 8760 = CF × capacity × 8760.
Problem 8. Load, demand and diversity factors from a daily load pattern MIST
Define load factor, demand factor and diversity factor; find the diversity factor if lighting is 150 kW (7–10 pm), residential 50 kW (7–12 pm) and pumping 75 kW (3–7 pm).
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| lighting | 150 kW, 7–10 pm | |
| residential | 50 kW, 7–12 pm | |
| pumping | 75 kW, 3–7 pm |
- diversity factor
- DF ≥ 1; the larger it is, the less capacity is needed.
- Find the combined peak from the time chart.
- Sum of peaks = 275 kW; system peak = 200 kW.
Problem 9. Diversity factor and load factor of a diesel station Practice problem
A diesel station supplies an industrial consumer (maximum demand 1500 kW), a commercial establishment (750 kW), domestic power (100 kW) and domestic lighting (450 kW). The maximum demand on the station is 2500 kW and it generates 45 × 10⁵ kWh a year. Find (i) the diversity factor and (ii) the annual load factor.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| MD₁…₄ | 1500, 750, 100, 450 kW | individual |
| MD | 2500 kW | station |
| E | 45 × 10⁵ kWh | annual |
- diversity factor
- LF
- DF (diversity) = Σ individual MD/system MD ≥ 1.
- LF = average/MD ≤ 1.
Problem 10. Load factor with a short evening peak EGCB
The daily base load of a system is 3500 MW. The load rises to 4000 MW at 6 PM only and stays there until 11 PM. Find the load factor.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| Pbase | 3500 MW | 24 h |
| Ppeak | 4000 MW | 6–11 pm |
- LF
- LF = energy/(peak × 24) for a day.
- A short peak barely lowers the LF.
- Energy = area under the load curve.
Problem 11. Annual load factor of a station that is shut down part of the time Practice problem
A 100 MW power station supplies 100 MW for 2 hours and 50 MW for 6 hours each day and is shut down for the rest of the day. It is also shut down for 45 days a year for maintenance. Find its annual load factor (based on the hours it is in operation).
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 100 MW for 2 h, 50 MW for 6 h | daily |
| shutdown | 45 days/year |
- annual LF
- LF = energy/(MD × hours considered).
- State the time base when the station is shut down part of the year.
Problem 12. Annual load factor from the daily load factor and the peak ratios Practice problem
Find the annual load factor of a system if the average daily load factor is 0.825, the ratio of the average daily peak load to the monthly peak load is 0.87, and the ratio of the average monthly peak load to the annual peak load is 0.78.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| LFd | 0.825 | daily |
| r₁ | 0.87 | daily/monthly peak |
| r₂ | 0.78 | monthly/annual peak |
- annual LF
- Annual LF = daily LF × (daily peak/monthly peak) × (monthly peak/annual peak).
- Annual LF < monthly LF < daily LF.
Problem 13. Maximum demand, daily energy, average load and load factor from a load cycle Practice problem
A generating station has the following daily load cycle: 0–6 h: 40 MW; 6–10 h: 50 MW; 10–12 h: 60 MW; 12–16 h: 50 MW; 16–20 h: 70 MW; 20–24 h: 40 MW. Draw the load curve and find (i) the maximum demand, (ii) the energy generated per day, (iii) the average load and (iv) the load factor.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| cycle | 40, 50, 60, 50, 70, 40 MW | in six periods (6, 4, 2, 4, 4, 4 h) |
- MD
- E
- Pavg
- LF
- Energy = Σ(load × hours).
- LF = average/peak.
Problem 14. Daily energy and average power of a household from its load curve Practice problem
A household uses 200 W from midnight to 6 a.m., 800 W from 6 to 8 a.m., 200 W from 8 a.m. to 6 p.m., 1200 W from 6 to 10 p.m. and 200 W from 10 p.m. to midnight. Find (a) the energy used in the day and (b) the average power.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| loads | 200, 800, 200, 1200, 200 W | for 6, 2, 10, 4, 2 h |
- E
- Pavg
- Energy = Σ P × t.
- Average = energy/time; load factor = average/peak.
Problem 15. Diversity factor and load factor from group loads Practice problem
A power station supplies four groups: A takes 200 kW from 8 am to 6 pm; B takes 100 kW from 6 am to 10 am; C takes 50 kW from 6 am to 10 am; D takes 100 kW from 10 am to 6 pm and again from 6 pm to 6 am. Plot the daily load curve and find (i) the diversity factor, (ii) the energy generated per day and (iii) the load factor.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| A | 200 kW, 8–18 h | |
| B | 100 kW, 6–10 h | |
| C | 50 kW, 6–10 h | |
| D | 100 kW, 10–6 h |
- diversity factor
- E
- LF
- Σ individual MD/simultaneous MD = diversity factor.
- Overlapping loads → build the total curve interval by interval.
Problem 16. Load factors of three consumers and of the station Practice problem
The daily demands of three consumers are: 12 midnight–8 am: consumer 1 none, consumer 2 200 W, consumer 3 none; 8 am–2 pm: 600 W, none, 200 W; 2 pm–4 pm: 200 W, 1000 W, 1200 W; 4 pm–10 pm: 800 W, none, none; 10 pm–midnight: none, 200 W, 200 W. Find (i) the maximum demand of each consumer, (ii) the load factor of each consumer, (iii) the diversity factor and (iv) the load factor of the station.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| consumer 1 | 0, 600, 200, 800, 0 W | |
| consumer 2 | 200, 0, 1000, 0, 200 W | |
| consumer 3 | 0, 200, 1200, 0, 200 W | |
| periods | 8, 6, 2, 6, 2 h |
- MD
- LF
- diversity factor
- station LF
- Consumer LF uses its own MD; station LF uses the simultaneous MD.
- Coinciding peaks → low diversity, low station load factor.
Problem 17. Load factor from the area of a load curve (planimeter) Practice problem
A daily load curve with a 15-minute peak of 3000 kW is drawn to a scale of 1 cm = 2 hours (horizontal) and 1 cm = 1000 kW (vertical). The area under the curve, measured with a planimeter, is 12 cm². Find the load factor based on the 15-minute peak.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| MD | 3000 kW | 15-min peak |
| scale | 1 cm = 2 h; 1 cm = 1000 kW | |
| A | 12 cm² | planimeter area |
- LF
- 1 cm² = (h/cm) × (kW/cm) kWh.
- Specify the demand interval when quoting a load factor.
Problem 18. Load factor, capacity factor and utilisation factor from a load-duration curve BCIC
A load-duration curve falls linearly from 20 MW to 4 MW. Three units (10, 10 and 5 MW) are installed. Find the load factor, capacity factor and utilization factor.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| LDC | 20 MW → 4 MW | linear |
| units | 10, 10, 5 MW | installed |
- LF
- CF
- UF
- Linear LDC: average = (Pmax + Pmin)/2.
- Reserve = capacity − peak = 5 MW.
- CF = LF × UF.
Problem 19. Annual energy and load factor from a linear load-duration curve DPDC
The annual load-duration curve of a substation is a straight line from 20 MW to 4 MW. Find the energy supplied in a year and the load factor.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| LDC | 20 MW → 4 MW | linear, annual |
- E
- LF
- Energy = area under the LDC.
- Average = (20 + 4)/2.
- MWh → GWh: ÷ 1000.
Problem 20. Plant capacity factor and load factor with a linear load curve BUET M.Sc.
Find the plant capacity factor and load factor of a 10 GW power station whose annual load varies linearly from 8 GW to 4 GW.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| C | 10 GW | capacity |
| load | 8 GW → 4 GW | linear |
- CF
- LF
- Linear variation: average = (max + min)/2.
- LF = avg/max; CF = avg/capacity.
- UF = 8/10 = 0.8 → CF = 0.75 × 0.8 = 0.6.
Problem 21. Load curve and load-duration curve of the same daily cycle Practice problem
A power station has the daily load cycle: 6–8 h: 20 MW; 8–12 h: 40 MW; 12–16 h: 60 MW; 16–20 h: 20 MW; 20–24 h: 50 MW; 24–6 h: 20 MW. Plot the load curve and the load-duration curve, and find the energy generated per day.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| cycle | 20, 40, 60, 20, 50, 20 MW | for 2, 4, 4, 4, 4, 6 h |
- E
- Load-duration curve = loads sorted in descending order.
- Same area as the chronological curve.
Problem 22. Maximum demand and annual energy from diversity factor NPCBL
A station supplies four areas with peaks of 10, 5, 8 and 7 MW. Diversity factor 1.5, annual load factor 60 %. Find the maximum demand and annual energy.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| peaks | 10, 5, 8, 7 MW | four areas |
| DF | 1.5 | diversity factor |
| LF | 60 % |
- MD
- E
- Station MD = Σ peaks/DF.
- Energy = MD × LF × 8760.
- 105.12 × 10⁶ kWh = 105.12 GWh.
Problem 23. Maximum demand, annual energy and unit sizes for a new station Practice problem
A power station is to supply four areas whose peak loads are 10 000 kW, 6000 kW, 8000 kW and 7000 kW. The diversity factor of the loads at the station is 1.5 and the annual load factor is 65 %. Find the maximum demand on the station and the annual energy supplied. Suggest the installed capacity, allowing for a 60 % increase in maximum demand, and suggest the type of station and the number and size of units.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| peaks | 10 000, 6000, 8000, 7000 kW | |
| DF | 1.5 | |
| LF | 65 % | |
| growth | 60 % |
- MD
- E
- installed capacity
- MD = Σ peaks/diversity factor.
- Installed capacity ≥ future MD + largest unit.
- Fewer, larger units → lower cost per kW; at least two units → spare.
Problem 24. Feeder maximum demand from group demand and diversity factors DWASA
A feeder supplies three transformers (connected load 10, 12, 15 kW; demand factors 0.65, 0.6, 0.7; diversity among each group 1.5, 3.5, 1.5). The diversity factor among transformers is 1.3. Find the feeder maximum load.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| connected | 10, 12, 15 kW | |
| demand factors | 0.65, 0.6, 0.7 | |
| group DF | 1.5, 3.5, 1.5 | |
| DFT | 1.3 | among transformers |
- feeder MD
- Demand factor multiplies; diversity factor divides.
- Apply each factor at its own level.
- Feeder MD = Σ(transformer MD)/DF.
Problem 25. Maximum demand of a residential area BPDB
A new residential area is added to the lines of a public utility: 1000 apartments each with a 4 kW connection, plus services of 250 kW. The demand factor, group diversity factor and peak diversity factor of these two types of load are 45 % and 75 %; 3.5 and 1.5; 1.4 and 1.1 respectively. Find the increase in peak demand on the station bus.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| apartments | 1000 × 4 kW | |
| services | 250 kW | |
| demand factor | 45 %, 75 % | |
| group DF | 3.5, 1.5 | |
| peak DF | 1.4, 1.1 |
- ΔMD (at the station bus)
- Demand factor ×, diversity factors ÷.
- Peak diversity factor = group MD/contribution to system peak.
- Answer ≈ 481 kW.
Problem 26. Group maximum demand of a commercial group EGCB
A commercial group has 12 consumers each with a connected load of 12 kW and a demand factor of 80 %. The group has a group diversity factor of 1.2 and a peak diversity factor of 1.1. Determine the demand of the consumer group at the time of system peak.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| N | 12 | consumers |
| P | 12 kW | each |
| DF | 80 % | demand factor |
| GDF | 1.2 | group diversity |
| 1.1 | peak diversity |
- demand at system peak
- Chain: × DF ÷ GDF ÷ PDF.
- Group MD = 96 kW.
- Contribution at system peak = 87.3 kW.
Problem 27. Increase in system peak from a residential-cum-shopping complex Practice problem
A new residential-cum-shopping complex is to be supplied from an existing distribution system. It has 600 apartments, each with a connected load of 5 kW. The shopping area has 20 general-purpose shops, each with a connected load of 2 kW and a demand factor of 0.8, and in addition: a flour mill (10 kW, demand factor 0.7), a saw mill (5 kW, 0.8), a laundry (20 kW, 0.65) and a cinema (80 kW, 0.5). Street lighting consists of 200 tube lights of 40 W each. For the residential load take a demand factor of 0.5, a group diversity factor of 3.0 and a peak diversity factor of 1.25. For the commercial load take a group diversity factor of 2.0 and a peak diversity factor of 1.6. For street lighting take all three factors as unity. Find the increase in the peak demand of the system caused by this complex.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| apartments | 600 × 5 kW; DF 0.5; GDF 3; PDF 1.25 | |
| commercial | shops and mills, total 96 kW; GDF 2; PDF 1.6 | |
| street lights | 200 × 40 W |
- ΔMD (system peak)
- Demand at system peak = Σ(connected × DF)/(group DF × peak DF).
- Street lighting usually has all factors = 1.
Problem 28. Maximum demand and connected loads from demand and diversity factors Practice problem
A supply system has three types of load: domestic (maximum demand 1500 kW, diversity within the group 1.2, demand factor 0.8), commercial (2000 kW, 1.1, 0.9) and industrial (10 000 kW, 1.25, 1.0). The overall system diversity factor is 1.35. Find (i) the maximum demand on the system and (ii) the connected load of each type.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| domestic | 1500 kW; GDF 1.2; DF 0.8 | |
| commercial | 2000 kW; 1.1; 0.9 | |
| industrial | 10 000 kW; 1.25; 1.0 | |
| system DF | 1.35 |
- MD
- connected loads
- Connected load × demand factor = individual MD.
- Σ individual MD ÷ diversity = combined MD.
Problem 29. Minimum capacity of a diesel station for a suburban area Practice problem
A diesel power station is to supply a suburban area with (i) 1000 houses, each with an average connected load of 1.5 kW, demand factor 0.4 and diversity factor 2.5; (ii) 10 factories with an overall maximum demand of 90 kW; (iii) 7 tube-wells of 7 kW each, all running together in the morning. The diversity factor among the three types of consumer is 1.2. What is the minimum capacity of the station?
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| houses | 1000 × 1.5 kW; DF 0.4; GDF 2.5 | |
| factories | 90 kW | overall MD |
| tube-wells | 7 × 7 kW | |
| DF | 1.2 | among groups |
- minimum capacity
- Loads switched on together → diversity factor 1.
- Capacity ≥ maximum demand (a reserve is added in practice).
Problem 30. Maximum demand from reserve capacity and factors NWPGCL
A power station has 3000 kW reserve capacity, 60 % load factor and 50 % plant capacity factor. Find the maximum demand.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| reserve | 3000 kW | |
| LF | 60 % | |
| CF | 50 % |
- MD
- UF = CF/LF = 0.5/0.6 = 0.833.
- Reserve = C(1 − UF).
- Check: 18 000 − 15 000 = 3000.
Problem 31. Station capacity from annual energy and factors EGCB
A station has an annual load factor of 0.7 and delivers 1000 million kWh a year; the utilization factor is 0.6. Find the station capacity.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| LF | 0.7 | |
| E | 1000 × 10⁶ kWh | annual |
| UF | 0.6 |
- C (station capacity)
- Average = energy/8760.
- MD = average/LF.
- Capacity = MD/UF.
Problem 32. Capacity and reserve of a peak-load hydro plant Practice problem
The annual load-duration curve of a small hydro plant shows 438 × 10⁴ kWh of energy during the year. It is a peak-load plant with a 20 % annual load factor. Find the maximum demand and the station capacity if the plant capacity factor is 15 %, and find the reserve capacity of the plant.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| E | 438 × 10⁴ kWh | annual |
| LF | 20 % | |
| CF | 15 % |
- MD
- C
- reserve
- MD = E/(LF × 8760).
- Capacity = E/(CF × 8760).
- Low LF is normal for peak-load plants.
Problem 33. Load factors and capacity factors of a base-load and a standby station Practice problem
A base-load station (18 MW) and a standby station (20 MW) share a common load. Annual output: standby 7.35 × 10⁶ kWh; base-load 101.35 × 10⁶ kWh. The peak load on the standby station is 12 MW and it runs for 2190 hours a year. Find the annual load factor and plant capacity factor of each station.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| base | 18 MW; 101.35 × 10⁶ kWh | |
| standby | 20 MW; 7.35 × 10⁶ kWh; peak 12 MW; 2190 h |
- LF
- CF (each station)
- PCF = LF × (MD/capacity) for the same time base.
- Base-load plant: high PCF; standby/peak plant: low PCF.
Problem 34. Reserve capacity and energy from the plant factors RPGCL
A generating station has a maximum demand of 25 MW, load factor 60 %, plant capacity factor 50 % and plant use factor 72 %. Find (a) the reserve capacity, (b) the daily energy produced, (c) the maximum energy that could be produced daily if the plant ran fully loaded.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| MD | 25 MW | |
| LF | 60 % | |
| CF | 50 % | |
| UFplant | 72 % | plant use factor |
- reserve
- daily E
- max daily E
- Plant use factor uses the hours actually run.
- Reserve = capacity − MD.
- Daily energy = average × 24.
Problem 35. Daily energy and reserve capacity of a power station PGCL
A power station has a maximum demand of 1500 kW, a load factor of 70 % and a plant capacity factor of 54.5 %. Find (i) the energy produced daily, (ii) the reserve capacity of the plant and (iii) the maximum energy that could have been produced daily if the plant ran all the time.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| MD | 1500 kW | |
| LF | 70 % | |
| CF | 54.5 % |
- daily E
- reserve
- max daily E
- Average = LF × MD.
- Capacity = average/CF.
- Max daily energy = capacity × 24.
Problem 36. Daily load factor, plant capacity factor and fuel per day Practice problem
A power station has the daily load cycle: 260 MW for 6 h, 200 MW for 8 h, 160 MW for 4 h and 100 MW for 6 h. It has four 75 MW units. The oil used has a calorific value of 10 000 kcal/kg and the station heat rate is 2860 kcal/kWh. Find (i) the daily load factor, (ii) the plant capacity factor and (iii) the oil needed per day.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| cycle | 260 MW 6 h; 200 MW 8 h; 160 MW 4 h; 100 MW 6 h | |
| units | 4 × 75 MW | |
| CV | 10 000 kcal/kg | |
| HR | 2860 kcal/kWh | heat rate |
- LF
- CF
- oil per day
- PCF = average/installed capacity.
- Fuel = heat rate × kWh ÷ CV.
Problem 37. Average cost per kWh from a two-part tariff BCPCL
A consumer has a maximum demand of 200 kW at 40 % load factor. The tariff is BDT 100 per kW of maximum demand per annum plus 10 paise per kWh. Find the overall cost per kWh.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| MD | 200 kW | |
| LF | 40 % | |
| tariff | BDT 100/kW/year + 10 paise/kWh |
- cost per kWh
- Higher load factor → lower cost per kWh (the kW charge is spread over more kWh).
- 100 paise = 1 Taka.
- Cost/kWh = A/(LF × 8760) + B.
Problem 38. Monthly bill with a demand charge and a two-block energy charge Practice problem
A two-part tariff has a demand charge of Tk 500 per kW of maximum demand per month and an energy charge of Tk 9 per kWh for the first 50 000 kWh and Tk 8 per kWh for the rest. Find the monthly bill and the average cost per kWh of (a) a factory that uses 200 MWh with a maximum demand of 1600 kW, and (b) a mill that uses 500 MWh with a maximum demand of 3200 kW.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| demand charge | Tk 500/kW/month | |
| energy | Tk 9 (first 50 000 kWh), Tk 8 (rest) | |
| (a) | 200 MWh, 1600 kW | |
| (b) | 500 MWh, 3200 kW |
- bill
- average cost
- Two-part tariff: Tk/kW (demand) + Tk/kWh (energy).
- Higher load factor → lower average cost per kWh.
Problem 39. Domestic bill with a fixed charge and three energy blocks Practice problem
A residential tariff has a fixed charge of Tk 120 per month and energy blocks: the first 100 kWh at Tk 4.00, the next 200 kWh at Tk 5.50, and every kWh above 300 at Tk 7.00. Find the bill for a month in which 700 kWh is used, and the average cost per kWh.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| fixed | Tk 120/month | |
| blocks | Tk 4.00 (100), 5.50 (200), 7.00 (rest) | |
| E | 700 kWh |
- bill
- average cost
- Block tariff: charge each slab separately.
- Average cost = bill ÷ units.
Problem 40. Thermal efficiency and coal cost of a station NWPGCL
A thermal station has a maximum demand of 20 000 kW, load factor 40 %, boiler efficiency 85 %, turbine efficiency 90 %, coal consumption 0.9 kg/kWh and coal cost 300 BDT per tonne. Find (i) the thermal efficiency and (ii) the coal bill per annum.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| MD | 20 000 kW | |
| LF | 40 % | |
| ηb | 85 % | boiler |
| ηt | 90 % | turbine |
| coal | 0.9 kg/kWh | |
| price | BDT 300/t |
- ηth
- coal bill
- Efficiencies in series multiply.
- 1 t = 1000 kg.
- Energy = MD × LF × 8760.
Problem 41. Calorific value of coal from overall efficiency and coal burnt per kWh Practice problem
A steam power station has an overall efficiency of 20 %, and 0.6 kg of coal is burnt for every kWh of electrical energy it generates. Find the calorific value of the coal.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| η | 20 % | overall efficiency |
| m | 0.6 kg/kWh | coal burnt |
| 1 kWh | 860 kcal |
- CV
- 1 kWh = 860 kcal.
- Overall η = 860/(specific coal consumption × CV).
- Heat rate (kcal/kWh) = 860/η.
Problem 42. Average load of a steam station from its annual coal bill Practice problem
A steam power station spends Tk 30 lakh a year on coal. The coal has a calorific value of 5000 kcal/kg and costs Tk 300 per tonne. The station has a thermal efficiency of 33 % and an electrical efficiency of 90 %. Find the average load on the station.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| bill | Tk 30 lakh/year | coal |
| CV | 5000 kcal/kg | |
| price | Tk 300/t | |
| ηth | 33 % | |
| ηe | 90 % |
- Pavg
- ηoverall = ηthermal × ηelectrical.
- kWh = kcal × η/860.
- Average load = annual kWh/8760.
Problem 43. Monthly fuel oil and overall efficiency of a diesel plant Practice problem
A diesel power plant has one 700 kW and two 500 kW generating units. The fuel consumption is 0.28 kg per kWh and the calorific value of the fuel oil is 10 200 kcal/kg. The plant capacity factor is 40 %. Estimate (i) the fuel oil needed for a 30-day month and (ii) the overall efficiency.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| units | 700 kW + 2 × 500 kW | |
| fuel | 0.28 kg/kWh | |
| CV | 10 200 kcal/kg | |
| CF | 40 % | |
| month | 30 days |
- fuel per month
- η
- Plant capacity factor = Eactual/(capacity × hours).
- η = 860/(kg per kWh × CV).
Problem 44. Probable forced outage of a generating system APSCL
A generating system has a total capacity of 300 MW. Find the probable forced outages when the capacity is supplied in one unit, and in two 150 MW units. The operating probability of each unit is P = 0.98 and the forced-outage probability is Q = 0.02.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| C | 300 MW | total |
| P | 0.98 | availability |
| Q | 0.02 | forced-outage probability |
- expected outage (1 × 300 and 2 × 150 MW)
- Expected value = Σ p × loss.
- Splitting capacity keeps the expectation but lowers the risk of total loss.
- P + Q = 1.
Problem 45. Energy intensity of a country PGCB
The population of Bangladesh is 150 million and its GDP is Tk 21 200 billion. The annual energy consumption is 642.17 × 10⁶ GJ. Calculate the energy intensity of Bangladesh.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| population | 150 million | |
| GDP | Tk 21 200 billion | |
| E | 642.17 × 10⁶ GJ | annual |
- energy intensity
- Energy intensity = energy/GDP (lower is more efficient).
- Per-capita energy = energy/population.
- Keep units: GJ per Tk.
Problem 46. Energy used by a set of bulbs TGTDCL
10 bulbs rated 220 V, 60 W burn for 10 hours. Find the units of electricity used.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| n | 10 | bulbs |
| P | 60 W | each |
| t | 10 h |
- energy
- 1 unit = 1 kWh.
- W → kW: ÷ 1000.
- The voltage rating is not needed.
- DC Circuit Analysis
- Network Theorems
- RL, RC & RLC Transients
- Single-Phase AC Circuits
- Series & Parallel Resonance
- Power Factor Correction
- Three-Phase Circuits
- Transformer
- DC Generator & DC Motor
- Three-Phase Induction Motor
- Synchronous Machines
- Diode Circuits
- BJT Biasing & Amplifiers
- MOSFET & Power Electronics
- Op-Amp Circuits
- AM, FM & Analog Modulation
- Signals and Sampling
- PCM, Delta Modulation & TDM
- Digital Communication & Telecom
- Load Curves & Power Generation (this post)
- Per-Unit & Transmission Lines
- Faults & Symmetrical Components
- Protection & Switchgear
- Control Systems
- Digital Logic & Microprocessors
- Measurement, Mechanics & Aptitude
Topics shown in grey are coming soon. See every post in this series.
Found a mistake or have a better method? Leave a comment below. More topics from the question bank are in the other posts of this series.
Thank you for visiting my blog.