Three-Phase Induction Motor question solutions for EEE job exams. 6 written questions and 33 math problems on Three-Phase Induction Motor, the kind asked in Bangladesh EEE recruitment exams (BPDB, PGCB, DPDC, DESCO, NWPGCL, EGCB, BCS and others), each solved in exam style: the given data, what is required, the formula used at every step, the substitution and the final answer.
This post is part 10 of the EEE Job Preparation Question Bank series. It covers the induction motor with 39 solved questions: 5 written (theory) questions and 17 math problems on slip, rotor current, power flow, torque and starting from recruitment exams (DPDC, BPDB, DWASA, BCIC, BAPEX) and BUET admission tests, plus 16 practice problems and 1 practice written question on the same topics.
The answers are written for learning, not only for checking. A written answer explains what the thing is, why it is so, how it works and where it is used; where a question says "draw", the diagram is built up one step at a time. A math solution is laid out the way an examiner wants to see it: the given data with symbols and values, the quantity required, and then each step as formula → substitution → result, with the reason for that step written beside it. It also shows how to think about that type of problem, a diagram, and what to keep in mind.
How to use this post: every answer is hidden. Try the question on paper first, then click Show full answer or Show step-by-step solution. The grey tag beside a question shows the exam it came from.
- Formulas to memorize first
- Part A: Written questions (6)
Show the list
- Why is the starting current of an induction motor higher than the…
- Draw an auto-transformer starter for a 3-phase induction motor and…
- Draw the schematic diagram of the no-load and blocked-rotor tests of a…
- Draw the equivalent circuit of a single-phase induction motor based on…
- Draw the torque-slip characteristics of a single-phase capacitor-start…
- A wound-rotor induction motor is running at about 25 % load with its…
- Part B: Solved problems (33)
Show the list
- Speed of an induction motor and effect of frequency
- Rated speed of an induction motor
- Speed, rotor frequency and shaft torque of a 10 hp motor
- Field speed, rotor speed, slip speed and rotor frequency (6-pole, 50 Hz)
- Speeds and rotor frequency of a 2-pole, 60 Hz motor
- Synchronous speed when the supply frequency is reduced
- Poles, slip and quarter-load speed from no-load and full-load speeds
- Slip, rotor frequency and speed regulation of a 2-pole motor
- Rotor frequency and rotor e.m.f. while running
- Shaft speed, power and torque of a 6-pole induction motor
- Speed and mechanical power of an induction motor
- Induction motor rotor current
- Slip and rotor current at maximum torque
- Rotor impedance and rotor current at two values of slip
- Induction-motor power flow
- Mechanical power from rotor copper loss and slip
- Mechanical power from the rotor copper loss (4.5 % slip)
- Rotor copper loss from the air-gap power
- Slip, induced torque and load torque from PAG and Pconv
- Speed, torques and rotor frequency of a 50 kW, 2-pole motor
- Torque and speed when the load torque is doubled
- Full equivalent-circuit solution of a 30 hp wound-rotor motor
- Stator resistance from a d.c. test on a delta-connected motor
- Mechanical power and rotor copper loss per phase
- Rotor input and speed of an induction motor
- Induction torque from the rotor copper loss
- Stator input of an induction motor
- Power factor of an induction motor
- Stator-voltage reduction for half-speed full-load torque
- External rotor resistance for 75 % starting torque
- Effect of doubling the rotor resistance on maximum and starting torque
- Speed of a 60 Hz motor run on a 50 Hz, 385 V supply
- Full-load current of an induction motor
- Other parts of this series
Formulas to Memorize First
- Synchronous speed: Ns = 120f/P. Slip: s = (Ns − N)/Ns, so N = Ns(1 − s).
- Rotor frequency: fr = sf. Rotor e.m.f. when running = sE2; rotor reactance when running = sX2.
- Rotor current: I2 = sE2/√(R2² + (sX2)²) = E2/√((R2/s)² + X2²).
- Power flow: input → (stator copper + core loss) → air-gap power Pag → (rotor copper loss) → mechanical power Pmech → (friction + windage) → shaft output.
- The 1 : s : (1 − s) rule: Pag : rotor copper loss : Pmech = 1 : s : (1 − s).
- Torque: T = Pag/ωs = Pmech/ωm, with ω = 2πN/60.
- Torque equation: T ∝ sE2²R2/(R2² + s²X2²), and T ∝ V².
- Maximum torque: at sm = R2/X2. Its value ∝ E2²/(2X2) and does not depend on R2.
- Input power: P = √3 VL IL cos φ. 1 hp = 746 W.
- Starting: direct-on-line current is 5 to 7 times full load. Star-delta gives 1/3 of the current and torque; an auto-transformer at tap x gives x².
Part A: Written Questions on Three-Phase Induction Motor
Q1. Why is the starting current of an induction motor higher than the required current? BUET Admission
Show full answer
Short answer (write this in the exam)
At the instant of starting the rotor is at rest, so the slip is 1. The rotating field cuts the rotor conductors at full synchronous speed and induces the largest possible rotor e.m.f. The rotor is a short-circuited winding of very low impedance, so a very large rotor current flows. By transformer action the stator must draw a correspondingly large current, typically 5 to 7 times the full-load current.
How to think about it: a transformer with a shorted secondary
An induction motor at standstill is a transformer whose secondary (the rotor) is short-circuited. A transformer with a shorted secondary on full voltage draws a huge current, and so does the motor. Once the rotor turns, it is as if the secondary e.m.f. were reduced to sE2, so the current falls.
Why the current falls as the motor speeds up
Rotor e.m.f. = sE2 and rotor current I2 = sE2/√(R2² + (sX2)²). As the speed rises, the slip falls from 1 to about 0.03 to 0.05, the relative speed between field and rotor falls, the induced e.m.f. falls, and the current comes down to its normal value. (A DC motor is similar: its starting current is high because there is no back e.m.f. at rest.)
Why the starting torque is still small
At start the rotor frequency equals the supply frequency, so the rotor reactance X2 is much larger than R2 and the rotor power factor is very low. Torque needs the in-phase part of the current (T ∝ ΦI2 cos φ2), so a large current gives only a moderate torque.
What is done about it
Large motors are started on reduced voltage (star-delta starter, auto-transformer starter, soft starter) or, for slip-ring motors, with resistance added to the rotor, which reduces the current and raises the starting torque at the same time.
Keep in mind
s = 1 at start → rotor e.m.f. is maximum → current 5 to 7 times full load, at a low power factor. The current is "higher than required" because most of it is reactive and produces little torque.
Q2. Draw an auto-transformer starter for a 3-phase induction motor and mention the starting sequence. DPDC
Show full answer
What it does
An auto-transformer starter applies a reduced voltage to the motor during starting, so the starting current is reduced, and then connects the motor to full voltage for running.
How to draw it (three steps, one phase shown)
Each picture adds one step to the one before it. Draw it on paper in the same order.
Starting sequence
- Close the main switch and the START contactor (and the star contactor of the auto-transformer). The motor starts on reduced voltage xV.
- The motor accelerates. Wait until it reaches about 80 % of full speed (a timer does this).
- Open the START contactor and close the RUN contactor. The motor is now on full line voltage and the auto-transformer is disconnected.
- To stop, open the RUN contactor. Overload and no-volt protection are included as in any starter.
How much the current and torque are reduced
| Quantity | Compared with direct-on-line starting |
|---|---|
| Motor voltage | x |
| Motor current | x |
| Line (supply) current | x² |
| Starting torque | x² |
Why x² for the line current: the motor current is x times, and the auto-transformer steps the current down by another factor x on the supply side. Why x² for torque: torque ∝ V². With a 65 % tap, the line current and torque are both 42 % of the direct-on-line values.
Where it is used
For large squirrel-cage motors where the supply cannot stand the direct-on-line current. Compared with a star-delta starter (fixed at 1/3), the tap can be chosen to suit the load, and it works whether the motor is star or delta connected.
Keep in mind
Sequence: START (reduced voltage) → accelerate → RUN (full voltage). Line current and torque both fall as x².
Q3. Draw the schematic diagram of the no-load and blocked-rotor tests of a 3-phase induction motor. BUET Admission
Show full answer
What the tests are for
They are the induction-motor versions of the transformer open-circuit and short-circuit tests. They give the equivalent-circuit parameters and the losses without loading the motor.
No-load test (like the open-circuit test)
- How: run the motor uncoupled at rated voltage and frequency. Read V0, I0 and P0 = W1 + W2.
- What happens: the slip is nearly zero, so R2/s is very large and the rotor branch is almost open.
- What the power is: core loss + friction and windage + a small stator copper loss.
- What you get: the shunt branch Rc and Xm, and the rotational losses.
Blocked-rotor test (like the short-circuit test)
- How: lock the rotor so it cannot turn. Raise the voltage from zero until rated current flows (about 15 to 25 % of rated voltage). Read Vsc, Isc and Psc quickly, before the motor heats up.
- What happens: s = 1, so the rotor branch is R2 + jX2, much smaller than the magnetising branch, which can be ignored.
- What the power is: stator plus rotor copper loss at rated current.
- What you get: R1 + R′2 = Psc/(3Isc²), and X1 + X′2 from the impedance triangle.
The third measurement
A DC resistance test on the stator gives R1 alone, so that R′2 can be separated from the total.
Keep in mind
No load ↔ open circuit ↔ shunt branch ↔ rated voltage. Blocked rotor ↔ short circuit ↔ series branch ↔ rated current.
Q4. Draw the equivalent circuit of a single-phase induction motor based on the double revolving field theory. BUET Admission
Show full answer
What the double revolving field theory says
A single-phase winding produces a field that only pulsates along one axis; it does not rotate. But a pulsating field can be resolved into two fields of half the amplitude rotating at synchronous speed in opposite directions: a forward field and a backward field. Each acts on the rotor like the field of a three-phase motor, so the single-phase motor behaves as two motors on one shaft pulling in opposite directions.
How to draw it (three steps)
Each picture adds one step to the one before it. Draw it on paper in the same order.
Why the backward slip is 2 − s
The rotor runs at N = Ns(1 − s) in the forward direction. The backward field runs at −Ns. The slip relative to it is (Ns + N)/Ns = 1 + (1 − s) = 2 − s.
What the circuit explains
- No starting torque: at standstill s = 1, so both blocks are identical, the forward and backward torques are equal and cancel.
- It runs once started: when the rotor is moving forward, s is small, so R′2/s is large and the forward block takes most of the voltage. The forward torque dominates. Net torque = Tf − Tb.
- Why an auxiliary winding is needed: to produce a true rotating field at start (split-phase, capacitor-start and so on).
Keep in mind
Two blocks in series, each with halves of Xm, X′2 and R′2. Forward uses s, backward uses 2 − s.
Q5. Draw the torque-slip characteristics of a single-phase capacitor-start, induction-run motor. EGCB
Show full answer
What the motor is
A single-phase motor with two windings: the main winding, and an auxiliary (starting) winding with a capacitor in series. The capacitor makes the auxiliary current lead the main current by nearly 90°, so the two windings together produce a rotating field and a high starting torque. A centrifugal switch disconnects the auxiliary winding once the motor is up to speed; after that it runs on the main winding alone ("induction run").
How to draw the curve (three steps)
Each picture adds one step to the one before it. Draw it on paper in the same order.
Drawing step 3 of 3. The motor follows the upper curve from standstill until the centrifugal switch opens at about 75 % of synchronous speed. There the torque drops straight down to the main-winding curve, and the motor follows that curve to its running speed. The thick line is the actual characteristic.Why the switch is needed
The starting capacitor is an electrolytic type rated only for short-time duty, and the auxiliary winding is of thin wire. Left in circuit, both would overheat. By 75 % speed the main winding alone gives enough torque.
Where it is used
Loads that are hard to start: compressors, refrigerators, air-conditioners, pumps and conveyors.
Keep in mind
Two curves and a step. Label the starting torque, the switching speed (about 75 %), the breakdown torque on the main-winding curve, and synchronous speed where the torque is zero.
Q6. A wound-rotor induction motor is running at about 25 % load with its slip rings shorted. If the rotor resistance is doubled by adding external resistors, what happens to the slip, speed, induced rotor voltage, rotor current, induced torque, output power, rotor copper loss and efficiency? Practice question
Show full answer
Key idea
At light load the motor works on the straight part of its torque–speed curve, where the induced torque is about T ∝ s/R2 (for fixed supply voltage). The load torque has not changed, so after the change the motor must again produce the same torque. If R2 doubles, s must double so that s/R2 stays the same.
| Quantity | What happens | Why |
|---|---|---|
| Slip s | About doubles | T ∝ s/R2 must stay equal to the load torque. |
| Speed nm | Falls | nm = (1 − s)ns; e.g. s from 1 % to 2 % moves the speed from 0.99ns to 0.98ns. |
| Induced rotor voltage | About doubles | Er = sEBR. |
| Rotor current | About the same | Ir ≈ sEBR/R2 at low slip; s and R2 both double. |
| Induced torque | Same | It must still balance the (unchanged) load torque. |
| Output power Pout | Falls a little | Same torque at a slightly lower speed. |
| Rotor copper loss PRCL | About doubles | PRCL = sPAG, and PAG = T ωs is unchanged. |
| Efficiency | Falls | Same input, more rotor loss, less output. |
Exam tip
Added rotor resistance is good for starting (higher starting torque, lower starting current) but wasteful for running. That is why the resistors of a wound-rotor motor are cut out once it is up to speed.
Part B: Solved Problems on Three-Phase Induction Motor
Problem 1. Speed of an induction motor and effect of frequency BCMCL
A 3-phase, 50 Hz, 8-pole induction motor has 3 % full-load slip. Find the full-load speed and the speed when the frequency is raised by 20 %.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| f | 50 Hz | supply |
| P | 8 | poles |
| s | 3 % | full-load slip |
| f₂ | 60 Hz | after +20 % |
- N (at 50 Hz and 60 Hz)
- Ns = 120f/P; N = Ns(1 − s).
- Speed of an induction motor is controlled mainly through frequency.
Problem 2. Rated speed of an induction motor DWASA
A 220 V, 4-pole, 50 Hz induction motor has 5 % slip. What is the rated motor speed?
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 4 | poles |
| f | 50 Hz | |
| s | 5 % | slip |
- N
- Common synchronous speeds at 50 Hz: 2 poles 3000, 4 poles 1500, 6 poles 1000, 8 poles 750 rpm.
Problem 3. Speed, rotor frequency and shaft torque of a 10 hp motor Practice problem
A 208 V, 10 hp, 4-pole, 60 Hz, Y-connected induction motor has a full-load slip of 5 %. Find (a) the synchronous speed, (b) the rotor speed at rated load, (c) the rotor frequency at rated load and (d) the shaft torque at rated load.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| V | 208 V | |
| Pout | 10 hp | 7460 W |
| P | 4 | poles |
| f | 60 Hz | |
| s | 5 % |
- ns
- nr
- fr
- T
- 1 hp = 746 W.
- T = P/ω with ω = 2πn/60.
- Rotor frequency at full load is only a few hertz.
Problem 4. Field speed, rotor speed, slip speed and rotor frequency (6-pole, 50 Hz) Practice problem
A 220 V, 3-phase, 6-pole, 50 Hz induction motor runs at a slip of 3.5 %. Find (a) the speed of the rotating magnetic field, (b) the rotor speed, (c) the slip speed of the rotor and (d) the rotor frequency.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 6 | poles |
| f | 50 Hz | |
| s | 3.5 % |
- ns
- nr
- slip speed
- fr
- ns = 120f/P; nr = (1 − s)ns.
- fr = sf = P(ns − nr)/120.
- The supply voltage (220 V) does not affect any speed here.
Problem 5. Speeds and rotor frequency of a 2-pole, 60 Hz motor Practice problem
A 480 V, 3-phase, 2-pole, 60 Hz induction motor runs at a slip of 0.025. Find the speed of the magnetic field, the rotor speed, the slip speed and the rotor frequency.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 2 | poles |
| f | 60 Hz | |
| s | 0.025 |
- ns
- nr
- slip speed
- fr
- Highest synchronous speeds: 3000 r.p.m. (50 Hz) and 3600 r.p.m. (60 Hz), both for 2 poles.
- Slip is a ratio; slip speed is in r.p.m.
Problem 6. Synchronous speed when the supply frequency is reduced Practice problem
A 6-pole, 460 V, 60 Hz induction motor is fed from a supply whose frequency is reduced to 85 % of its rated value. What is the new synchronous speed?
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 6 | poles |
| f | 60 Hz | rated |
| f′ | 0.85f | reduced |
- ns′
- ns ∝ f for a given number of poles.
- For speed control by frequency, keep V/f constant so the core is not saturated.
Problem 7. Poles, slip and quarter-load speed from no-load and full-load speeds Practice problem
A 3-phase, 60 Hz induction motor runs at 715 r.p.m. at no load and at 670 r.p.m. at full load. (a) How many poles does it have? (b) What is the slip at rated load? (c) What is the speed at one-quarter of rated load? (d) What is the rotor frequency at one-quarter load?
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| f | 60 Hz | |
| nnl | 715 rpm | no load |
| nfl | 670 rpm | full load |
- P
- sFL
- n (at ¼ load)
- fr (at ¼ load)
- ns is always a little above the no-load speed.
- Low-slip region: T ∝ s (at constant voltage).
Problem 8. Slip, rotor frequency and speed regulation of a 2-pole motor Practice problem
A 3-phase, 60 Hz, 2-pole induction motor runs at 3580 r.p.m. at no load and 3440 r.p.m. at full load. Find the slip and the rotor frequency at no load and at full load, and the speed regulation.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 2 | poles |
| f | 60 Hz | |
| nnl | 3580 rpm | no load |
| nfl | 3440 rpm | full load |
- s, fr (no load and full load)
- SR
- SR = (nnl − nfl)/nfl × 100 %.
- Slip at no load is almost zero but never exactly zero.
Problem 9. Rotor frequency and rotor e.m.f. while running Practice problem
A 6-pole, 60 Hz wound-rotor induction motor has a rotor frequency of 60 Hz and a rotor induced voltage of 100 V when its shaft is blocked. Find the rotor frequency and rotor voltage when the rotor runs at 1100 r.p.m.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 6 | poles |
| f | 60 Hz | |
| EBR | 100 V | blocked-rotor e.m.f. |
| nr | 1100 rpm | running speed |
- fr
- Er
- fr = sf and Er = sEBR.
- Rotor reactance also scales: Xr = sXBR.
Problem 10. Shaft speed, power and torque of a 6-pole induction motor PGCL
A 50 kW, 400 V, 50 Hz, 6-pole induction motor has a full-load slip of 6 %, friction loss 300 W and (stator) loss 600 W. Find (i) the shaft speed, (ii) the motor output power, (iii) the induced torque and (iv) the load torque. (The 50 kW is taken as the electrical input.)
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| Pin | 50 kW | electrical input |
| V | 400 V | |
| f | 50 Hz | |
| P | 6 | poles |
| s | 6 % | |
| Pf | 300 W | friction |
| Ps | 600 W | stator loss |
- N
- Pout
- Tind
- Tload
- Tind = Pag/ωs = Pconv/ωm.
- Tload = Pout/ωm.
Problem 11. Speed and mechanical power of an induction motor BPDB
A three-phase, 460 V, 25 hp, 60 Hz, four-pole induction motor operating at reduced load requires 14.58 kW input to its rotor. The rotor copper losses are 263 W and the friction, windage and stray power losses are 197 W. Determine the shaft speed and the mechanical power developed in the motor.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| PAG | 14.58 kW | rotor input |
| PRCL | 263 W | rotor copper loss |
| Pfws | 197 W | friction, windage, stray |
| P | 4 | poles |
| f | 60 Hz |
- N
- Pconv
- s = Prcl/Pag.
- Pag : Prcl : Pconv = 1 : s : (1 − s).
Problem 12. Induction motor rotor current DWASA
A 3-phase slip-ring induction motor has a star-connected rotor with 120 V induced emf between slip rings at standstill, R₂ = 0.3 Ω and X₂ = 1.5 Ω per phase. Find the rotor current per phase when running short-circuited at 4 % slip.
Figure: per-phase rotor circuit at slip sShow step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| E₂L | 120 V | slip-ring voltage at standstill (Y rotor) |
| R₂ | 0.3 Ω | per phase |
| X₂ | 1.5 Ω | per phase |
| s | 4 % |
- I₂
- I2 = sE2/√(R2² + (sX2)²).
- Convert line to phase values before using per-phase R and X.
Problem 13. Slip and rotor current at maximum torque BCIC
For the slip-ring motor of Problem 12 (E₂ = 69.28 V/phase, R₂ = 0.3 Ω, X₂ = 1.5 Ω) find the slip and rotor current at maximum torque.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| E₂ | 69.28 V | per phase at standstill |
| R₂ | 0.3 Ω | |
| X₂ | 1.5 Ω |
- sm
- I₂ (at maximum torque)
- sm = R2/X2.
- At maximum torque the rotor power factor is 0.707.
- Tmax does not depend on R2; only the slip at which it occurs does.
Problem 14. Rotor impedance and rotor current at two values of slip Practice problem
The rotor of a 25 hp, 6-pole, 60 Hz induction motor has a resistance of 0.10 Ω and a blocked-rotor reactance of 0.54 Ω per phase. The blocked-rotor voltage per phase is 150 V. For a rotor speed of 1164 r.p.m. find (a) the synchronous speed, (b) the slip, (c) the rotor impedance and (d) the rotor current. (e) If a change of load makes the slip 1.24 %, find the new rotor current and (f) the new speed.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 6 | poles |
| f | 60 Hz | |
| Rr | 0.10 Ω | |
| XBR | 0.54 Ω | |
| EBR | 150 V | per phase |
| nr | 1164 rpm | |
| s′ | 1.24 % | new slip |
- ns
- s
- Zr
- Ir
- Ir′
- nr′
- Rotor current: Ir = EBR/(Rr/s + jXBR).
- Low slip: Ir ≈ sEBR/Rr, nearly in phase with EBR.
- Halving the slip roughly halves the rotor current and the torque.
Problem 15. Induction-motor power flow BCIC
A 480 V, 60 Hz, 50 hp, three-phase induction motor draws 60 A at 0.85 power factor lagging. Stator copper loss is 2 kW, rotor copper loss 700 W, friction and windage 600 W, core loss 1800 W; stray loss is negligible. Find (a) the air-gap power, (b) the converted power, and, as an extension, (c) the output power and efficiency.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| VL | 480 V | |
| IL | 60 A | |
| pf | 0.85 lagging | |
| PSCL | 2 kW | stator copper |
| PRCL | 700 W | rotor copper |
| Pfw | 600 W | |
| Pcore | 1800 W |
- PAG
- Pconv
- Pout, η
- Order of losses: stator copper, core, rotor copper, friction and windage, stray.
- 1 hp = 746 W.
Problem 16. Mechanical power from rotor copper loss and slip RPGCL
The rotor copper loss of a three-phase induction motor is 300 W. For a slip of 40 % find the electrical power converted to mechanical power.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| Prcl | 300 W | rotor copper loss |
| s | 0.40 | slip |
- Pmech
- Pmech = Prcl × (1 − s)/s.
- A 40 % slip is far from normal running; it wastes 40 % of the rotor input as heat.
Problem 17. Mechanical power from the rotor copper loss (4.5 % slip) BCIC, BIFPCL
The rotor copper loss of a 3-phase induction motor is 300 W. For a slip of 4.5 % calculate the electrical power converted to mechanical power.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| Prcl | 300 W | rotor copper loss |
| s | 0.045 | slip |
- Pmech
- Rotor efficiency = 1 − s. Small slip means an efficient rotor.
Problem 18. Rotor copper loss from the air-gap power Practice problem
The input power to the rotor circuit of a 6-pole, 60 Hz induction motor running at 1100 r.p.m. is 5 kW. What is the rotor copper loss?
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 6 | poles |
| f | 60 Hz | |
| nr | 1100 rpm | |
| PAG | 5 kW | rotor input |
- PRCL
- PRCL = sPAG; Pconv = (1 − s)PAG.
- A motor running at high slip wastes a large share of its rotor input as heat.
Problem 19. Slip, induced torque and load torque from PAG and Pconv Practice problem
In a 60 Hz, 4-pole induction motor the air-gap power is 25 kW and the power converted from electrical to mechanical form is 23.2 kW. (a) What is the slip? (b) What is the induced torque? (c) If the mechanical losses are 300 W at this slip, what is the load torque?
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| f | 60 Hz | |
| P | 4 | poles |
| PAG | 25 kW | |
| Pconv | 23.2 kW | |
| Pmech | 300 W | mechanical losses |
- s
- Tind
- Tload
- Tind = PAG/ωs = Pconv/ωr.
- Tload = Pout/ωr, always a little less than Tind.
Problem 20. Speed, torques and rotor frequency of a 50 kW, 2-pole motor Practice problem
A 50 kW, 460 V, 50 Hz, 2-pole induction motor runs at a slip of 5 % at full load. At full load the friction and windage losses are 700 W and the core losses are 600 W. Find (a) the shaft speed, (b) the output power, (c) the load torque, (d) the induced torque and (e) the rotor frequency.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| Pout | 50 kW | rated output |
| f | 50 Hz | |
| P | 2 | poles |
| s | 5 % | |
| Pfw | 700 W | |
| Pcore | 600 W |
- n
- Pout
- Tload
- Tind
- fr
- Tload = Pout/ωr; Tind = Pconv/ωr.
- Rotational loss = friction + windage (+ core loss if lumped).
Problem 21. Torque and speed when the load torque is doubled Practice problem
A 2-pole, 50 Hz induction motor supplies 15 kW to a load at 2950 r.p.m. (a) What is the slip? (b) What is the induced torque? (c) What will the speed be if the load torque is doubled? (d) How much power will the motor then supply? (Neglect mechanical losses.)
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 2 | poles |
| f | 50 Hz | |
| Pout | 15 kW | |
| n | 2950 rpm |
- s
- T
- n (at double torque)
- P (at double torque)
- Low slip: T ∝ s, so s2/s1 = T2/T1.
- P = Tω — remember the speed also changes.
Problem 22. Full equivalent-circuit solution of a 30 hp wound-rotor motor Practice problem
A 208 V, 4-pole, 60 Hz, Y-connected wound-rotor induction motor is rated at 30 hp. Its per-phase equivalent circuit has R1 = 0.100 Ω, X1 = 0.210 Ω, R2 = 0.070 Ω, X2 = 0.210 Ω and XM = 10.0 Ω. Mechanical losses are 500 W, core losses 400 W and stray losses negligible. For a slip of 0.05 find (a) the line current, (b) the stator copper loss, (c) the air-gap power, (d) the converted power, (e) the induced torque, (f) the load torque, (g) the efficiency and (h) the speed in r.p.m. and rad/s.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| VL | 208 V | Y |
| P | 4 | poles |
| f | 60 Hz | |
| R1, X1 | 0.100 Ω, 0.210 Ω | |
| R2, X2 | 0.070 Ω, 0.210 Ω | |
| XM | 10.0 Ω | |
| Pmech | 500 W | |
| Pcore | 400 W | |
| s | 0.05 |
- IL
- PSCL
- PAG
- Pconv
- Tind
- Tload
- η
- n
- RF (real part of ZF) absorbs exactly PAG/3 per phase.
- Tind = PAG/ωs.
- Check with power balance: Pin − losses = Pout.
Problem 23. Stator resistance from a d.c. test on a delta-connected motor Practice problem
A d.c. test is carried out on a 460 V, Δ-connected, 100 hp induction motor. A d.c. voltage of 21 V is applied across two terminals and the current is 72 A. What is the stator resistance per phase, and why is the answer not simply 21/72?
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| Vdc | 21 V | test voltage |
| Idc | 72 A | test current |
| connection | Δ |
- R1 (per phase)
- Star: Rdc = 2R1. Delta: Rdc = 2R1/3.
- The d.c. test gives the stator resistance only; the blocked-rotor test then gives R2.
Problem 24. Mechanical power and rotor copper loss per phase BAPEX
The power input to a 3-phase induction motor is 60 kW and the stator losses total 1 kW. Find the mechanical power developed and the rotor copper loss per phase if the motor runs with a slip of 3 %.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| Pin | 60 kW | input |
| Ps | 1 kW | stator losses |
| s | 3 % |
- Pmech
- Pcu2 (per phase)
- "Per phase" in a three-phase machine: divide the total by 3.
Problem 25. Rotor input and speed of an induction motor BPDB
A 3-phase induction motor is running at 2.5 % slip. The output of the rotor is 3 kW. What is the rotor input? What is the speed of the motor if it has 4 poles and the supply frequency is 50 Hz?
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| s | 2.5 % | slip |
| Pm | 3 kW | rotor output |
| P | 4 | poles |
| f | 50 Hz |
- Pin,rotor
- N
- Rotor input = rotor output/(1 − s).
Problem 26. Induction torque from the rotor copper loss BUET Admission
Determine the induction torque in a 400 V, 50 Hz, 4-pole, Y-connected induction motor operating at 2 % slip with 240 W being lost in its rotor winding.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| V | 400 V | |
| f | 50 Hz | |
| P | 4 | poles |
| s | 2 % | |
| Pcu2 | 240 W | rotor copper loss |
- Tind
- Tind = Pag/ωs. Because of this, air-gap power is sometimes called "torque in synchronous watts".
Problem 27. Stator input of an induction motor BWDB, BPDB
A 3-phase, 4-pole, 50 Hz induction motor develops 10 hp at 1000 rpm. Find the stator input if the stator loss is 100 W.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 4 | poles |
| f | 50 Hz | |
| Pm | 10 hp | developed |
| N | 1000 rpm | |
| Ps | 100 W | stator loss |
- Pin (stator input)
- Pag = Pmech/(1 − s).
- 1 hp = 746 W.
Problem 28. Power factor of an induction motor DESCO
A 3-phase, 5 hp, 220 V Y-connected motor has an efficiency of 85 %. Determine the power factor when it draws 15 A from the line.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| Pout | 5 hp | output |
| VL | 220 V | |
| η | 85 % | |
| IL | 15 A |
- pf
- Motor nameplate power = output. Input = output/η.
Problem 29. Stator-voltage reduction for half-speed full-load torque DNCC
The rotor resistance and standstill reactance of a 3-phase induction motor are 0.015 Ω and 0.09 Ω per phase. At normal voltage the full-load slip is 3 %. Estimate the percentage reduction in stator voltage needed to develop full-load torque at half full-load speed, and the power factor.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| R₂ | 0.015 Ω | per phase |
| X₂ | 0.09 Ω | standstill |
| s₁ | 3 % | full-load slip |
| N₂ | ½Nfl | target speed |
- % voltage reduction
- rotor pf
Torque against speed at rated and at reduced voltage. The same full-load torque is reached at s = 0.03 on one curve and s = 0.515 on the other.- T ∝ V² · sR2/(R2² + s²X2²).
- Reducing the stator voltage is a poor way to control speed: high slip, high rotor loss, low power factor.
Problem 30. External rotor resistance for 75 % starting torque DPDC
A 4-pole, 50 Hz, 3-phase induction motor has a rotor resistance of 0.03 Ω and reactance of 0.12 Ω per phase. Find the external resistance per phase to be inserted to obtain 75 % of maximum torque at start.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| R₂ | 0.03 Ω | rotor resistance per phase |
| X₂ | 0.12 Ω | reactance per phase |
| Tst | 0.75Tmax | required |
- Rext (per phase)
Torque against speed for three rotor resistances. Two different resistances give 75 % of maximum torque at start.- Tst/Tmax = 2a/(1 + a²) with a = Rt/X2.
- Both 0.236 Ω and 0.024 Ω satisfy the equation. The usual answer quotes the smaller one, because it needs less resistance and wastes less power; state both if the question does not say.
- Tst = Tmax when Rt = X2.
Problem 31. Effect of doubling the rotor resistance on maximum and starting torque Practice problem
A 460 V, 25 hp, 60 Hz, 4-pole, Y-connected wound-rotor induction motor has R1 = 0.641 Ω, X1 = 1.106 Ω, R2 = 0.332 Ω, X2 = 0.464 Ω and XM = 26.3 Ω per phase (referred to the stator). Its Thevenin equivalent seen by the rotor is VTH = 255.2 V, RTH = 0.590 Ω and XTH = 1.106 Ω. With the normal rotor resistance the maximum torque is 229 N·m at a slip of 0.198. If the rotor resistance is doubled, at what speed does the maximum torque now occur, how large is it, and what is the new starting torque? Compare with the starting torque before the change.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| VTH | 255.2 V | |
| RTH | 0.590 Ω | |
| XTH | 1.106 Ω | |
| R2 | 0.332 Ω → 0.664 Ω | doubled |
| X2 | 0.464 Ω | |
| Tmax | 229 N·m at s = 0.198 | original |
- smax, n
- Tmax
- Tst (before and after)
Doubling R2 keeps the peak at 229 N·m but moves it from 1444 to about 1087 r.p.m., and the starting torque rises from 104 to about 170 N·m.- smax ∝ R2; Tmax is independent of R2.
- Maximum starting torque is obtained when smax = 1, i.e. R2 = √(RTH² + (XTH + X2)²).
- Extra rotor resistance also increases slip and rotor copper loss when running.
Problem 32. Speed of a 60 Hz motor run on a 50 Hz, 385 V supply Practice problem
A 40 hp, 460 V, 60 Hz, 4-pole, design B induction motor runs at 1770 r.p.m. when delivering rated output at rated voltage and frequency. It is now operated at 5/6 of rated horsepower from a 385 V, 50 Hz supply. Find (a) the shaft speed and (b) the slip.
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 40 hp | rated |
| V | 460 V, 60 Hz | rated |
| n | 1770 rpm | at rated |
| new supply | 385 V, 50 Hz | |
| load | 5/6 rated |
- n
- s
- Low slip: T ∝ V²s/f.
- Power ∝ T × speed.
- Reject the quadratic root that gives a large slip.
Problem 33. Full-load current of an induction motor BPDB
What is the full-load current of a 50 HP, 50 Hz, 0.85 p.f. induction motor when the line voltage is 415 V?
Show step-by-step solution
| Symbol | Value | Meaning |
|---|---|---|
| P | 50 hp | output |
| f | 50 Hz | |
| pf | 0.85 | |
| VL | 415 V |
- IL
- I = Pin/(√3 VL cos φ), with Pin = output/η.
- A quick rule at 415 V: about 1.2 to 1.4 A per hp.
- DC Circuit Analysis
- Network Theorems
- RL, RC & RLC Transients
- Single-Phase AC Circuits
- Series & Parallel Resonance
- Power Factor Correction
- Three-Phase Circuits
- Transformer
- DC Generator & DC Motor
- Three-Phase Induction Motor (this post)
- Synchronous Machines
- Diode Circuits
- BJT Biasing & Amplifiers
- MOSFET & Power Electronics
- Op-Amp Circuits
- AM, FM & Analog Modulation
- Signals and Sampling
- PCM, Delta Modulation & TDM
- Digital Communication & Telecom
- Load Curves & Power Generation
- Per-Unit & Transmission Lines
- Faults & Symmetrical Components
- Protection & Switchgear
- Control Systems
- Digital Logic & Microprocessors
- Measurement, Mechanics & Aptitude
Topics shown in grey are coming soon. See every post in this series.
Found a mistake or have a better method? Leave a comment below. More topics from the question bank are in the other posts of this series.
Thank you for visiting my blog.